Literature DB >> 1612962

Improved methods for determination of variability in patient positioning for radiation therapy using simulation and serial portal film measurements.

S A Rosenthal1, J M Galvin, J W Goldwein, A R Smith, P H Blitzer.   

Abstract

Variability in patient positioning was determined by analyzing simulation and portal film measurements for 318 portals in 51 patients treated with external beam radiotherapy to the head and neck. Several indicators of error in patient positioning were examined: random error, a measure of the deviation of all portal films from the average portal film position, systematic error, a measure of the difference between the average portal film and the simulation film, and total uncertainty, a measure of the overall deviation, including both random and systematic uncertainties. The median differences noted were 0.4 cm, 0.6 cm, and 0.7 cm, for Random Error, Systematic Error, and Total Uncertainty, respectively. The treatment fields analyzed in this study show a substantial treatment-to-treatment and simulation-to-treatment variability in patient positioning. The methods described provide an improved means for the systematic analysis of variability in patient positioning.

Entities:  

Mesh:

Year:  1992        PMID: 1612962     DOI: 10.1016/0360-3016(92)90020-i

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  8 in total

1.  HIT '91 (prospective, co-operative study for the treatment of malignant brain tumors in childhood): accuracy and acute toxicity of the irradiation of the craniospinal axis. Results of the quality assurance program.

Authors:  R D Kortmann; B Timmermann; J Kühl; N Willich; M Flentje; C Meisner; M Bamberg
Journal:  Strahlenther Onkol       Date:  1999-04       Impact factor: 3.621

2.  Immediate breast reconstruction-impact on radiation management.

Authors:  Ravi A Shankar; J Rao Nibhanupudy; Rajagopalan Sridhar; Cori Ashton; Alfred L Goldson
Journal:  J Natl Med Assoc       Date:  2003-04       Impact factor: 1.798

3.  Patient-specific daily pretreatment setup protocol using electronic portal imaging for radiation therapy.

Authors:  Michael H Wittmer; Thomas M Pisansky; Jon J Kruse; Michael G Herman
Journal:  J Appl Clin Med Phys       Date:  2005-11-21       Impact factor: 2.102

4.  Guide to clinical use of electronic portal imaging.

Authors:  M G Herman; J J Kruse; C R Hagness
Journal:  J Appl Clin Med Phys       Date:  2000       Impact factor: 2.102

5.  Site-specific tolerance tables and indexing device to improve patient setup reproducibility.

Authors:  Kiernan T McCullough; Joshua A James; Ashley J Cetnar; Mark A McCullough; Brian Wang
Journal:  J Appl Clin Med Phys       Date:  2015-05-08       Impact factor: 2.102

6.  Dosimetric Effects of the Interfraction Variations during Whole Breast Radiotherapy: A Prospective Study.

Authors:  Julian Jacob; Steve Heymann; Isabelle Borget; Isabelle Dumas; Elyes Riahi; Pierre Maroun; Patrick Ezra; Elena Roberti; Sofia Rivera; Eric Deutsch; Céline Bourgier
Journal:  Front Oncol       Date:  2015-09-16       Impact factor: 6.244

7.  Characterization and evaluation of 2.5 MV electronic portal imaging for accurate localization of intra- and extracranial stereotactic radiosurgery.

Authors:  Kwang Hyun Song; Karen Chin Snyder; Jinkoo Kim; Haisen Li; Wen Ning; Robert Rusnac; Paul Jackson; James Gordon; Salim M Siddiqui; Indrin J Chetty
Journal:  J Appl Clin Med Phys       Date:  2016-07-08       Impact factor: 2.102

8.  A method to predict patient-specific table coordinates for quality assurance in external beam radiation therapy.

Authors:  Daniel L Saenz; Nestor Rodrigo Astorga; Neil Kirby; Mohamad Fakhreddine; Karl Rasmussen; Sotirios Stathakis; Niko Papanikolaou
Journal:  J Appl Clin Med Phys       Date:  2018-08-07       Impact factor: 2.102

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.