Literature DB >> 16127196

Extrathoracic subclavian venipuncture under ultrasound guidance.

Kazumasa Orihashi1, Katsuhiko Imai, Katsutoshi Sato, Masaki Hamamoto, Kenji Okada, Taijiro Sueda.   

Abstract

BACKGROUND: Cardiac pacemaker and defibrillator leads are inserted through extrathoracic subclavian venipuncture using ultrasound (US) guidance, but there can be complications. The purpose of this study was to investigate a safer and improved implanting procedure. METHODS AND
RESULTS: Venipuncture guided by US with a 7.5 MHz convex transducer was performed to implant 32 leads in 18 patients. US enabled identification and location of the vein and needle tip during puncture and clarified the reasons for unsuccessful venipuncture. Venipuncture was successful on the second attempt or within 2 min in 90.6% (29/32) and 84.4% (27/32) of lead placements, respectively, although the vein was small (mean, 7.8 mm), deep (mean, 22.7 mm), and required a large angle of entry (mean, 52.4). The subclavian artery or lung was adjacent to the vein in 50.0% and 27.8% of cases, respectively. The flexible wall of the vein interfered with the penetration of the needle in 33.3% of cases. It was often difficult to locate the needle tip because of poor visualization.
CONCLUSIONS: Ultrasound guidance of subclavian venipuncture enables a safe and time-saving procedure by visualizing not only the needle but also the vein and surrounding structures, although further modifications of the needle are needed for better visualization.

Entities:  

Mesh:

Year:  2005        PMID: 16127196     DOI: 10.1253/circj.69.1111

Source DB:  PubMed          Journal:  Circ J        ISSN: 1346-9843            Impact factor:   2.993


  5 in total

1.  Evaluation of vascular puncture needles with specific modifications for enhanced ultrasound visibility: In vitro study.

Authors:  Nobuyuki Kawai; Hiroki Minamiguchi; Morio Sato; Motoki Nakai; Hiroki Sanda; Takami Tanaka; Akira Ikoma; Kouhei Nakata; Shintaro Shirai; Tetsuo Sonomura
Journal:  World J Radiol       Date:  2012-06-28

2.  Efficacy of ultrasound-guided axillary/subclavian venous approaches for pacemaker and defibrillator lead implantation: a randomized study.

Authors:  Mattia Liccardo; Pasquale Nocerino; Salzano Gaia; Carmine Ciardiello
Journal:  J Interv Card Electrophysiol       Date:  2018-01-15       Impact factor: 1.900

3.  Ultrasound-guided versus landmark-guided femoral vein access in pediatric cardiac catheterization.

Authors:  S Iwashima; T Ishikawa; T Ohzeki
Journal:  Pediatr Cardiol       Date:  2007-09-13       Impact factor: 1.655

4.  [Ultrasound-guided infraclavicular venipuncture at the junction of the axillary and subclavian veins].

Authors:  P Gaus; B Heß; H Müller-Breitenlohner
Journal:  Anaesthesist       Date:  2015-02       Impact factor: 1.041

5.  A Practical Guide to Ultrasound-guided Venous Access During Implantation of Pacemakers and Defibrillators.

Authors:  Dingxin Qin; Leon M Ptaszek
Journal:  J Innov Card Rhythm Manag       Date:  2022-02-15
  5 in total