Literature DB >> 16124159

Catheter fracture and cardiac migration--an unusual fracture site of totally implantable venous devices: report of two cases.

Chia-Lo Chang1, Hong-Hwa Chen, Shung-Eing Lin.   

Abstract

Totally implantable venous devices (TIVDs) are used increasingly in patients with cancers and other debilitating diseases requiring long-term chemotherapy, total parental nutrition, and fluid replacement. The TIVDs are surgically inserted and fixed in the soft tissues of the chest wall to prevent infection and accidental dislodgment. Acute and chronic complications associated with these catheters include infection, thrombosis, venous perforation, catheter leakage, dislodgment and fall out, subintimal entrapment, and tip migration to neighboring veins after satisfactory initial placement. Catheter fracture and cardiac migration is a rare complication and most reported cases have developed between the clavicle and the first rib as a consequence of a pinch-off sign. We present two patients with metastatic colon cancers with unusual catheter fracture site and migration and discuss the clinical implications.

Entities:  

Mesh:

Year:  2005        PMID: 16124159

Source DB:  PubMed          Journal:  Chang Gung Med J        ISSN: 2072-0939


  5 in total

1.  Lasso technique for retrieving a broken, dislocated port-a-cath fragment.

Authors:  N R Bindraban; H A van de Klippe; P F M M van Bergen; D C G Basart
Journal:  Neth Heart J       Date:  2009-02       Impact factor: 2.380

Review 2.  Management of Accidental and Iatrogenic Foreign Body Injuries to Heart- Case Series.

Authors:  Rupesh Kumar; Sandeep Singh Rana; Sanjay Kumar; Deepanwita Das; Monalisa Datta
Journal:  J Clin Diagn Res       Date:  2017-03-01

3.  Performance of venous port catheter insertion by a general surgeon: a prospective study.

Authors:  Mehmet Aziret; Oktay İrkörücü; Cihan Gökler; Enver Reyhan; Süleyman Çetinkünar; Timuçin Çil; Edip Akpınar; Hasan Erdem; Kamuran Cumhur Değer
Journal:  Int Surg       Date:  2015-05

4.  A single-center study of vascular access sites for intravenous ports.

Authors:  Ching-Feng Wu; Po-Jen Ko; Ching-Yang Wu; Yun-Hen Liu; Tsung-Chi Kao; Sheng-Yueh Yu; Hao-Jui Li; Hung-Chang Hsieh
Journal:  Surg Today       Date:  2013-05-14       Impact factor: 2.549

5.  Traumatic fracture of central venous catheter resulting in potential migration of distal fragment: a case report.

Authors:  Shailendra Deep; Sanjay Deshpande; Philip Howe
Journal:  Cases J       Date:  2008-12-14
  5 in total