A serrated jaw clamp for tendon gripping.

Jason Tak-Man Cheung1, Ming Zhang.   

Abstract

Mechanical testing of tendon and application of muscular tendon forces in cadaveric or animal studies requires the use of a clamp to hold the tendon rigidly at high loads without damaging it. Frozen type serrated clamp was able to achieve the objective but is less readily available and manageable because of its complex and massive configuration. In this study, a custom-made, serrated jaw clamp was fabricated. Maximum tension before visual slippage was monitored during tensile testing of a bovine tendon. The non-frozen serrated jaw clamp was able to sustain tension forces of more than 2500 N and strain of about 30% without slippage and cutting of the tendon. The jaw clamp can be easily customised and fabricated for biomechanical studies to hold tendons of different sizes. The commercially available, serrated plastic material enables the jaw clamp to be custom-made with minimal workmanship and manufacturing time.

Entities:  

Mesh:

Year:  2005        PMID: 16122965     DOI: 10.1016/j.medengphy.2005.07.010

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  5 in total

1.  Can the gracilis replace the anterior cruciate ligament in the knee? A biomechanical study.

Authors:  Etienne Cavaignac; Regis Pailhé; Nicolas Reina; Jérôme Murgier; Jean Michel Laffosse; Philippe Chiron; Pascal Swider
Journal:  Int Orthop       Date:  2015-11-05       Impact factor: 3.075

2.  The use of 2D ultrasound elastography for measuring tendon motion and strain.

Authors:  Laura Chernak Slane; Darryl G Thelen
Journal:  J Biomech       Date:  2013-11-28       Impact factor: 2.712

3.  Mechanical properties of tyramine substituted-hyaluronan enriched fascia extracellular matrix.

Authors:  Likang Chin; Anthony Calabro; Esteban Walker; Kathleen A Derwin
Journal:  J Biomed Mater Res A       Date:  2012-01-11       Impact factor: 4.396

4.  Templated freezing: a simple method may increase gripping force of the clamp on the tendon.

Authors:  T Wang; H Yu
Journal:  J Orthop Surg Res       Date:  2022-06-15       Impact factor: 2.677

5.  Biomechanical effects of stitches on the intra-articular mid-substance of quadruple hamstring-tendon grafts for anterior cruciate ligament reconstruction - a pilot comparative cadaveric study.

Authors:  Maurise Saur; Philippe Clavert; François Bonnomet; Henri Favreau; Matthieu Ehlinger
Journal:  Knee Surg Relat Res       Date:  2020-07-29