Literature DB >> 16122806

The effects of interelectrode distance on electromyographic amplitude and mean power frequency during incremental cycle ergometry.

Moh H Malek1, Terry J Housh, Jared W Coburn, Joseph P Weir, Richard J Schmidt, Travis W Beck.   

Abstract

The purpose of this study was to examine the effects of interelectrode distance (IED) on the relationships of absolute and normalized EMG amplitude and mean power frequency (MPF) versus power output during incremental cycle ergometry. Eleven adults (mean +/- S.D. age = 24.2 +/- 2.6 y; V(O2max) = 49.4 +/- 8.3 ml kg(-1) min(-1)) performed incremental cycle ergometry tests. Surface EMG signals were recorded simultaneously from bipolar electrode arrangements placed over the VL muscle with IEDs of 20, 40, and 60 mm. Polynomial regression analyses were used to describe the relationships for absolute and normalized EMG amplitude (muV(rms) and % max) and MPF (Hz and % max) versus power output (%max) for each subject at the three IEDs. In addition, separate one-way repeated measures ANOVAs were used to examine mean differences between the three IEDs for absolute and normalized EMG amplitude and MPF at power outputs of 80, 110, 140, and 170 W. The results of the polynomial regression revealed that the best fit model for each IED for the absolute and normalized EMG amplitude was linear for six of the 11 subjects and quadratic for five of the subjects. For EMG MPF, four of the 11 subjects exhibited significant relationships (linear or quadratic) across power outputs for at least one IED. The one-way repeated measures ANOVAs revealed significant mean differences between the IEDs for absolute EMG amplitude and MPF at 80, 110, 140, and 170 W. There were no significant mean differences, however, between the IEDs for normalized EMG amplitude or MPF at 80, 110, 140, and 170 W. The results of the study indicated that there were no consistent patterns of responses between individual subjects for EMG amplitude or MPF versus power output relationships for IEDs of 20, 40, and 60 mm during incremental cycle ergometry. The current findings supported the process of normalization for EMG amplitude and MPF data obtained during cycle ergometry when comparisons are made for different IEDs.

Mesh:

Year:  2005        PMID: 16122806     DOI: 10.1016/j.jneumeth.2005.06.025

Source DB:  PubMed          Journal:  J Neurosci Methods        ISSN: 0165-0270            Impact factor:   2.390


  4 in total

1.  Factors underlying the perception of effort during constant heart rate running above and below the critical heart rate.

Authors:  Haley C Bergstrom; Terry J Housh; Kristen C Cochrane; Nathaniel D M Jenkins; Jorge M Zuniga; Samuel L Buckner; Jacob A Goldsmith; Richard J Schmidt; Glen O Johnson; Joel T Cramer
Journal:  Eur J Appl Physiol       Date:  2015-06-25       Impact factor: 3.078

2.  Inter-individual variability in the patterns of responses for electromyography and mechanomyography during cycle ergometry using an RPE-clamp model.

Authors:  Kristen C Cochrane-Snyman; Terry J Housh; Cory M Smith; Ethan C Hill; Nathaniel D M Jenkins; Richard J Schmidt; Glen O Johnson
Journal:  Eur J Appl Physiol       Date:  2016-06-20       Impact factor: 3.078

3.  The Effect of Skinfold on the Assessment of the Mean Power Frequency at the Fatigue Threshold.

Authors:  Alyssandra N Baniqued; Jorge M Zuniga; Thomas C Strunc; Katie M Keenan; Agrini K Boken; Jeffrey J Anderson
Journal:  Int J Exerc Sci       Date:  2016-10-01

Review 4.  Strategies for cardiopulmonary exercise testing of pectus excavatum patients.

Authors:  Moh H Malek; Jared W Coburn
Journal:  Clinics (Sao Paulo)       Date:  2008-04       Impact factor: 2.365

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.