Literature DB >> 16120912

Optimization of MDCT of the wrist to achieve diagnostic image quality with minimum radiation exposure.

Harald Marcel Bonel1, Lorenz Jäger, Kathrin Anne Frei, Stefan Galiano, Sudesh K Srivastav, Thomas Flohr, Maximilian F Reiser, Hans-Peter Dinkel.   

Abstract

OBJECTIVE: This study tests various acquisition and reconstruction protocols for MDCT of the wrist to determine the optimal protocol for obtaining diagnostic image quality with minimal radiation exposure.
MATERIALS AND METHODS: Thirty anatomic specimens were examined with an MDCT collimation of 4.0 x 1.0 mm and 2.0 x 0.5 mm (80, 120, and 140 kV; 80, 100, 130, 160, and 200 mA; rotation time, 0.5 0.75, 1.0 sec; pitch, 1.0, 1.3, 1.5, and 2.0). Coronal images were reconstructed using a slice thickness of 0.5, 1.0, and 2.0 mm with 60% overlap. Three observers evaluated all images independently for gross and fine anatomic detail. Diagnostic confidence was tested using Shrout-Fleiss intraclass correlation coefficients. Interobserver agreement was assessed by Kappa statistics and the Kruskal-Wallis test.
RESULTS: Fine anatomic detail was best presented in 0.5-mm or 1.00-mm reconstructions based on a 2.0 x 0.5 mm acquisition. A rotation time of > or = 0.75 sec resulted in fewer artifacts; a significant dose reduction was achieved with 80 kV and 100 mA at the expense of somewhat increased noise, but without significant loss of anatomic detail in bone presentation. Artifacts were tolerable with a pitch of 1.5 or less.
CONCLUSION: MDCT at the described optimal settings allows significant dosage reduction without sacrificing image quality. An acquisition and reconstruction thickness of 0.5 mm results in the best depiction of anatomic detail. A reconstruction thickness of 1.0 mm with a reconstruction interval of 0.5 mm represents a good trade-off between noise and resolution when using low-dose protocols.

Mesh:

Year:  2005        PMID: 16120912     DOI: 10.2214/ajr.185.3.01850647

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  5 in total

Review 1.  CT of the musculoskeletal system: what is left is the days of MRI?

Authors:  A T H West; T J Marshall; P W Bearcroft
Journal:  Eur Radiol       Date:  2008-08-09       Impact factor: 5.315

Review 2.  MDCT in the evaluation of skeletal trauma: principles, protocols, and clinical applications.

Authors:  Mats Geijer; Georges Y El-Khoury
Journal:  Emerg Radiol       Date:  2006-08-24

3.  Whole-body computed tomography for multiple traumas using a triphasic injection protocol.

Authors:  Christos Loupatatzis; Sebastian Schindera; Jan Gralla; Hanno Hoppe; Jan Bittner; Ralph Schröder; Sudesh Srivastav; Harald Marcel Bonel
Journal:  Eur Radiol       Date:  2008-02-13       Impact factor: 5.315

4.  A CT method for following patients with both prosthetic replacement and implanted tantalum beads: preliminary analysis with a pelvic model and in seven patients.

Authors:  Henrik Olivecrona; Gerald Q Maguire; Marilyn E Noz; Michael P Zeleznik; Uldis Kesteris; Lars Weidenhielm
Journal:  J Orthop Surg Res       Date:  2016-02-24       Impact factor: 2.359

5.  Are CT Scans a Satisfactory Substitute for the Follow-Up of RSA Migration Studies of Uncemented Cups? A Comparison of RSA Double Examinations and CT Datasets of 46 Total Hip Arthroplasties.

Authors:  Volker Otten; Gerald Q Maguire; Marilyn E Noz; Michael P Zeleznik; Kjell G Nilsson; Henrik Olivecrona
Journal:  Biomed Res Int       Date:  2017-01-24       Impact factor: 3.411

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.