Literature DB >> 16119485

Patient-controlled epidural analgesia following combined spinal-epidural analgesia in labour: the effects of adding a continuous epidural infusion.

C Missant1, A Teunkenst, E Vandermeersch, M Van de Velde.   

Abstract

Patient-controlled epidural analgesia (PCEA) is used to maintain epidural analgesia following initial intrathecal analgesia. This trial investigated whether a continuous background infusion with PCEA provides superior analgesia to PCEA alone among patients who received combined spinal-epidural (CSE) analgesia during labour Eighty parturients were randomized to either PCEA alone (PCEA) or PCEA with a background infusion of ropivacaine 0.15% with sufentanil 0.75 microg/ml at 2 ml/h (PCEA + CEI). PCEA settings were a bolus of 4 ml of the same analgesic solution with a lockout interval of 15 minutes. Significantly more patients in the PCEA group required at least one anaesthetist intervention for breakthrough pain (27 [71%] vs 10 [25%] in the PCEA + CEI group, P<0.05). Consumption of local anaesthetic (excluding manually administered boluses) was similar between the groups. If anaesthetist-administered boluses were included, more local anaesthetic was consumed by the PCEA group (47.1 +/- 19.4 mg vs 35.6 +/- 12.0 mg in the PCEA + CEI group, P<0.05). We conclude that PCEA with a background infusion provides effective analgesia with less anaesthetist workload and reduced local anaesthetic consumption as compared with PCEA without a background infusion.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16119485     DOI: 10.1177/0310057X0503300405

Source DB:  PubMed          Journal:  Anaesth Intensive Care        ISSN: 0310-057X            Impact factor:   1.669


  5 in total

1.  Patient intermittent epidural boluses (PIEB) plus very low continuous epidural infusion (CEI) versus patient-controlled epidural analgesia (PCEA) plus continuous epidural infusion (CEI) in primiparous labour: a randomized trial.

Authors:  Maria Belen Rodríguez-Campoó; Antonio Curto; Manuel González; Cesar Aldecoa
Journal:  J Clin Monit Comput       Date:  2018-11-30       Impact factor: 2.502

Review 2.  [Recent standards in management of obstetric anesthesia].

Authors:  Maximiliaan van Erp; Clemens Ortner; Stefan Jochberger; Klaus Ulrich Klein
Journal:  Wien Med Wochenschr       Date:  2017-07-25

Review 3.  A Review of the Impact of Obstetric Anesthesia on Maternal and Neonatal Outcomes.

Authors:  Grace Lim; Francesca L Facco; Naveen Nathan; Jonathan H Waters; Cynthia A Wong; Holger K Eltzschig
Journal:  Anesthesiology       Date:  2018-07       Impact factor: 7.892

4.  Comparison of computer-integrated patient-controlled epidural analgesia with no initial basal infusion versus moderate basal infusion for labor and delivery: A randomized controlled trial.

Authors:  Ban Leong Sng; David Woo; Wan Ling Leong; Hao Wang; Pryseley Nkouibert Assam; Alex Th Sia
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2014-10

Review 5.  [Neuraxial labor analgesia: a literature review].

Authors:  Fábio Farias de Aragão; Pedro Wanderley de Aragão; Carlos Alberto Martins; Karlla Fernanda Custódia Silva Leal; Alexandro Ferraz Tobias
Journal:  Braz J Anesthesiol       Date:  2019-02-15
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.