Two-dimensional ultrasound receive array using an angle-tuned Fabry-Perot polymer film sensor for transducer field characterization and transmission ultrasound imaging.

Paul Christopher Beard1.   

Abstract

A 2-D optical ultrasound receive array has been investigated. The transduction mechanism is based upon the detection of acoustically induced changes in the optical thickness of a thin polymer film acting as a Fabry-Perot sensing interferometer (FPI). By illuminating the sensor with a large-area laser beam and mechanically scanning a photodiode across the reflected output beam, while using a novel angle-tuned phase bias control system to optimally set the FPI working point, a notional 2-D ultrasound array was synthesized. To demonstrate the concept, 1-D and 2-D ultrasound field distributions produced by planar 3.5-MHz and focused 5-MHz PZT ultrasound transducers were mapped. The system was also evaluated by performing transmission ultrasound imaging of a spatially calibrated target. The "array" aperture, defined by the dimensions of the incident optical field, was elliptical, of dimensions 16 x 12 mm and spatially sampled in steps of 0.1 mm or 0.2 mm. Element sizes, defined by the photodiode aperture, of 0.8, 0.4, and 0.2 mm were variously used for these experiments. Two types of sensor were evaluated. One was a discrete 75-microm-thick polyethylene terephthalate FPI bonded to a polymer backing stub which had a wideband peak noise-equivalent pressure of 6.5 kPa and an acoustic bandwidth 12 MHz. The other was a 40-microm Parylene film FPI which was directly vacuum-deposited onto a glass backing stub and had an NEP of 8 kPa and an acoustic bandwidth of 17.5 MHz. It is considered that this approach offers an alternative to piezoelectric ultrasound arrays for transducer field characterization, transmission medical and industrial ultrasound imaging, biomedical photoacoustic imaging, and ultrasonic nondestructive testing.

Entities:  

Year:  2005        PMID: 16118981     DOI: 10.1109/tuffc.2005.1504022

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  3 in total

1.  High-resolution ultrasonic imaging using an etalon detector array.

Authors:  Sheng-Wen Huang; Yang Hou; Shai Ashkenazi; Matthew O'Donnell
Journal:  Appl Phys Lett       Date:  2008-09-15       Impact factor: 3.791

2.  An acousto-optic sensor based on resonance grating waveguide structure.

Authors:  Antonio Jou Xie; Fuchuan Song; Sang-Woo Seo
Journal:  Sens Actuators A Phys       Date:  2014-09-01       Impact factor: 3.407

3.  An integrated optoacoustic transducer combining etalon and black PDMS structures.

Authors:  Yang Hou; Shai Ashkenazi; Sheng-Wen Huang; Matthew O'Donnell
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2008-12       Impact factor: 2.725

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.