Literature DB >> 16117464

Embol-X intra-aortic filtration system: capturing particulate emboli in the cardiac surgery patient.

Michael A Sobieski1, Patroklos S Pappas, Antone J Tatooles, Mark S Slaughter.   

Abstract

We sought to evaluate the effectiveness of using an intra-aortic filtration system for the prevention of particulate emboli transport and the minimization of significant postoperative complications associated with particulate emboli. Between October of 2000 and October 2001, a total of 146 patients were enrolled at Advocate Christ Medical Center as part of the multi-institutional randomized trial (1289 patients at 22 centers). A total of 74 patients (51%) received the Embol-X intra-aortic filter and 72 patients (49%) were enrolled in the control group. Patients were evaluated for neurological deficit, myocardial infarction, renal insufficiency/failure, limb ischemia, and death at 12-hour, 24-hour, 72-hour, 7-day, and 30-day postoperative intervals. All filters received histological examination for particulate matter. Particulate matter was isolated in 70 (94.5%) of the filters successfully deployed. There was no statistically significant difference in the device related events between the filter and conventional cannulation groups (9/74 = 12.1% vs. 7/72 = 9.7%). Although not clinically evident, the primary event for both groups was ascending aortic intimal tears. There was one death in each of the groups not related to the filter or cannula used. The use of the Embol-X intra-aortic filter system has proven to be a safe and effective means to reduce the introduction of particulate emboli into the systemic circulation. Clearly, the reduction of particulate matter by as much as 95% justifies its use in cardiac surgery patients identified with an increased pre-operative embolic risk.

Entities:  

Mesh:

Year:  2005        PMID: 16117464      PMCID: PMC4682540     

Source DB:  PubMed          Journal:  J Extra Corpor Technol        ISSN: 0022-1058


  22 in total

1.  "Off-pump" coronary artery bypass grafting: the first one hundred cases of the Rose City experience.

Authors:  W F Turner
Journal:  Ann Thorac Surg       Date:  1999-10       Impact factor: 4.330

2.  Longitudinal assessment of neurocognitive function after coronary-artery bypass surgery.

Authors:  M F Newman; J L Kirchner; B Phillips-Bute; V Gaver; H Grocott; R H Jones; D B Mark; J G Reves; J A Blumenthal
Journal:  N Engl J Med       Date:  2001-02-08       Impact factor: 91.245

3.  The extracorporeal pump filter--saint or sinner?

Authors:  R Heimbecker; A Robert; F N McKenzie
Journal:  Ann Thorac Surg       Date:  1976-01       Impact factor: 4.330

4.  Atheroembolism from the ascending aorta. An emerging problem in cardiac surgery.

Authors:  C I Blauth; D M Cosgrove; B W Webb; N B Ratliff; M Boylan; M R Piedmonte; B W Lytle; F D Loop
Journal:  J Thorac Cardiovasc Surg       Date:  1992-06       Impact factor: 5.209

5.  A decade of change--risk profiles and outcomes for isolated coronary artery bypass grafting procedures, 1990-1999: a report from the STS National Database Committee and the Duke Clinical Research Institute. Society of Thoracic Surgeons.

Authors:  T Bruce Ferguson; Bradley G Hammill; Eric D Peterson; Elizabeth R DeLong; Frederick L Grover
Journal:  Ann Thorac Surg       Date:  2002-02       Impact factor: 4.330

6.  Impact of embolization during coronary artery bypass grafting on outcome and length of stay.

Authors:  D Barbut; Y W Lo; J P Gold; R R Trifiletti; F S Yao; D N Hager; R B Hinton; O W Isom
Journal:  Ann Thorac Surg       Date:  1997-04       Impact factor: 4.330

7.  Stroke after conventional versus minimally invasive coronary artery bypass.

Authors:  Sotiris C Stamou; Kathleen A Jablonski; Albert J Pfister; Peter C Hill; Mercedes K C Dullum; Ammar S Bafi; Steven W Boyce; Kathleen R Petro; Paul J Corso
Journal:  Ann Thorac Surg       Date:  2002-08       Impact factor: 4.330

8.  Cerebral emboli detected during bypass surgery are associated with clamp removal.

Authors:  D Barbut; R B Hinton; T P Szatrowski; G S Hartman; M Bruefach; P Williams-Russo; M E Charlson; J P Gold
Journal:  Stroke       Date:  1994-12       Impact factor: 7.914

9.  Arterial line filtration protects brain microcirculation during cardiopulmonary bypass in the pig.

Authors:  J Waaben; H R Sørensen; U L Andersen; K Gefke; J Lund; S Aggestrup; B Husum; H Laursen; A Gjedde
Journal:  J Thorac Cardiovasc Surg       Date:  1994-04       Impact factor: 5.209

10.  Microemboli during coronary artery bypass grafting. Genesis and effect on outcome.

Authors:  R E Clark; J Brillman; D A Davis; M R Lovell; T R Price; G J Magovern
Journal:  J Thorac Cardiovasc Surg       Date:  1995-02       Impact factor: 5.209

View more
  1 in total

1.  Clinical Predictors for Procedural Stroke and Implications for Embolic Protection Devices during TAVR: Results from the Multicenter Transcatheter Aortic Valve Replacement In-Hospital Stroke (TASK) Study.

Authors:  Anat Berkovitch; Amit Segev; Elad Maor; Alexander Sedaghat; Ariel Finkelstein; Matteo Saccocci; Ran Kornowski; Azeem Latib; Jose M De La Torre Hernandez; Lars Søndergaard; Darren Mylotte; Niels Van Royen; Azfar G Zaman; Pierre Robert; Jan-Malte Sinning; Arie Steinvil; Francesco Maisano; Katia Orvin; Gianmarco Iannopollo; Dae-Hyun Lee; Ole De Backer; Federico Mercanti; Kees van der Wulp; Joy Shome; Didier Tchétché; Israel M Barbash
Journal:  J Pers Med       Date:  2022-06-28
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.