Literature DB >> 16115434

Salvage of failed neuropathic ankle fractures: use of large-fragment fibular plating and multiple syndesmotic screws.

Mark D Perry1, Warren S Taranow, Arthur Manoli, James B Carr.   

Abstract

The purpose of this study was to develop a salvage procedure for failed fixation of ankle fractures that occurs in patients with sensory neuropathy. Six patients, with insensitivity to a 5.07 monofilament on the plantar surface of their foot (five with diabetes mellitus, one with alcoholic peripheral neuropathy) presented to a foot and ankle referral center with failed traditional fixation of their Weber B and C ankle fractures. Five fractures were the result of trauma. One fracture occurred without a discernable traumatic event. A laterally placed 4.5 DCP plate on the fibula with multiple 4.5-mm syndesmotic screws engaging both cortices of the tibia was used as fixation. All patients postoperatively were immobilized in a non-weight-bearing below-knee cast for a minimum of 3 months after surgery. At follow-up, all six patients were satisfied with their results as determined by aligned, functional, and asymptomatic limbs. The patients were especially pleased that after multiple attempts to provide stability to their fractured neuropathic ankles, they had retained their own legs and did not need an amputation. Fibular plate fixation using multiple large-fragment syndesmotic screws provides a reasonable salvage alternative for neuropathic patients with ankle fractures that failed using traditional hardware techniques.

Entities:  

Mesh:

Year:  2005        PMID: 16115434

Source DB:  PubMed          Journal:  J Surg Orthop Adv        ISSN: 1548-825X


  8 in total

1.  Fibula-pro-tibia in plating tibial non-unions.

Authors:  Galal Z Said; Mohammad M El-Sharkawi; Hatem G Said; Omar A Refai
Journal:  Int Orthop       Date:  2011-02-12       Impact factor: 3.075

Review 2.  Special Considerations in the Management of Diabetic Ankle Fractures.

Authors:  Jeffrey M Manway; Cody D Blazek; Patrick R Burns
Journal:  Curr Rev Musculoskelet Med       Date:  2018-09

3.  Percutaneous injection of bone marrow mesenchymal stem cells for ankle non-unions decreases complications in patients with diabetes.

Authors:  Philippe Hernigou; Isaac Guissou; Yasuhiro Homma; Alexandre Poignard; Nathalie Chevallier; Helene Rouard; Charles Henri Flouzat Lachaniette
Journal:  Int Orthop       Date:  2015-03-22       Impact factor: 3.075

4.  The Charcot foot in diabetes.

Authors:  Lee C Rogers; Robert G Frykberg; David G Armstrong; Andrew J M Boulton; Michael Edmonds; Georges Ha Van; Agnes Hartemann; Frances Game; William Jeffcoate; Alexandra Jirkovska; Edward Jude; Stephan Morbach; William B Morrison; Michael Pinzur; Dario Pitocco; Lee Sanders; Dane K Wukich; Luigi Uccioli
Journal:  Diabetes Care       Date:  2011-09       Impact factor: 19.112

5.  Combined circular external fixation and open reduction internal fixation with pro-syndesmotic screws for repair of a diabetic ankle fracture.

Authors:  Zacharia Facaros; Crystal L Ramanujam; John J Stapleton
Journal:  Diabet Foot Ankle       Date:  2010-10-18

6.  Primary Arthrodesis for Diabetic Ankle Fractures.

Authors:  Caleb W Grote; William Tucker; Kelly Stumpff; Mitchell C Birt; Greg A Horton
Journal:  Foot Ankle Orthop       Date:  2020-03-24

7.  Trans-calcaneal retrograde nailing for secondary-displaced traumatic ankle fractures in diabetics with insensate feet: a less-invasive salvage-arthrodesis technique.

Authors:  Ahmad El-Tantawy; Ashraf Atef; Ahmed Samy
Journal:  Eur J Orthop Surg Traumatol       Date:  2021-03-09

Review 8.  Inpatient management of diabetic foot disorders: a clinical guide.

Authors:  Dane K Wukich; David G Armstrong; Christopher E Attinger; Andrew J M Boulton; Patrick R Burns; Robert G Frykberg; Richard Hellman; Paul J Kim; Benjamin A Lipsky; James C Pile; Michael S Pinzur; Linda Siminerio
Journal:  Diabetes Care       Date:  2013-09       Impact factor: 19.112

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.