Literature DB >> 16113930

Influence of cervical preflaring on determination of apical file size in maxillary premolars: SEM analysis.

Juliana Machado Barroso1, Danilo M Zanello Guerisoli, Alexandre Capelli, Paulo César Saquy, Jesus Djalma Pécora.   

Abstract

The purpose of this study was to investigate the influence of cervical preflaring on the determination of the first file that binds at working length (WL) in buccal roots of maxillary premolars. Five groups (n=10) were formed at random and, after standard access cavities, the WL was determined 1 mm short from the apex. In group 1, the initial apical file was inserted without preflaring of cervical and middle thirds of the root canals. In groups 2 to 5, the cervical and middle thirds were enlarged with sizes 90 and 110 Gates-Glidden drills, K(3) Orifice Opener instruments, ProTaper instruments and LA Axxess burs, respectively. Canals were sized manually with K-files, starting with No. 08 K-files inserted passively up to the WL. File sizes were increased until a binding sensation was felt at the WL and the size of the instrument was recorded. Transversal sections of the WL regions were examined under scanning electron microscopy and the discrepancies between the canal diameter and first file to bind at the WL were assessed. Significant differences (p<0.001) were found between the groups. The major discrepancy was found without preflaring (mean 157.8 microm). LA Axxess burs produced the smallest discrepancy (mean 0.8 microm). Gates-Glidden drills and K(3) Orifice Opener instruments showed no significant differences (p>0.05) between their results (83.2 microm and 73.6 microm, respectively). The discrepancy for ProTaper instruments was 35.4 microm on average. In conclusion, the instrument binding technique for determination of the anatomical diameter at the WL was not precise. Preflaring of the cervical and middle thirds improved the determination of the anatomical diameter at the WL, and the type of instrument played a major role. Canals preflared with LA Axxess burs showed a more accurate binding of the files to anatomical diameter.

Entities:  

Mesh:

Year:  2005        PMID: 16113930     DOI: 10.1590/s0103-64402005000100005

Source DB:  PubMed          Journal:  Braz Dent J        ISSN: 0103-6440


  5 in total

1.  Influence of different methods of cervical flaring on establishment of working length.

Authors:  Dieison Nardi Lazzaretti; Bernardo Alievi Camargo; Alvaro Della Bona; Volmir João Fornari; José Roberto Vanni; Flares Baratto Filho
Journal:  J Appl Oral Sci       Date:  2006-10       Impact factor: 2.698

2.  The minimum residual root thickness after using ProTaper, RaCe and Gates-Glidden drills: A cone beam computerized tomography study.

Authors:  Nahid Mohammadzadeh Akhlaghi; Laleh Mohammadian Bajgiran; Amirali Naghdi; Elaheh Behrooz; Zohreh Khalilak
Journal:  Eur J Dent       Date:  2015 Apr-Jun

3.  Influence of cervical preflaring using different rotary instruments on the accuracy of apical file size determination: A comparative in-vitro study.

Authors:  Shiv Aditya Sharma; Shashi Prabha Tyagi; Dakshita Joy Sinha; Udai Pratap Singh; Priyanka Chandra; Gagandeep Kaur
Journal:  J Conserv Dent       Date:  2014-11

4.  CBCT Assessment of Root Dentine Removal by Gates-Glidden Drills and Two Engine-Driven Root Preparation Systems.

Authors:  Azade Harandi; Fatemeh Mohammadpour Maleki; Ehsan Moudi; Maryam Ehsani; Soraya Khafri
Journal:  Iran Endod J       Date:  2017

5.  Working length changes in curved canals after coronal flaring by using rotary files and hand file: An in vitro study.

Authors:  Rahul Kumar; Neha Khambete; Suvarna Patil; Upendra Hoshing; Ashish Medha; Roshan Shetty
Journal:  J Conserv Dent       Date:  2013-09
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.