Literature DB >> 16112976

Safe femoral pin placement in knee navigation surgery: a cadaver study.

D C Marchant1, D P Rimmington, I Nusem, R W Crawford.   

Abstract

A number of navigation systems used for total knee replacement surgery currently require the insertion of a distal femoral reference sensor pin, which is placed anterior to posterior just superior to the level of the knee joint. There is potential for the posterior neurovascular bundle to be damaged during the insertion of this sensor device. The aim of this cadaveric study was to identify the structures at risk during insertion of the distal femoral sensor, and determine whether a safe zone for insertion could be identified. Sixteen cadaveric lower limbs (8 pairs) were studied. In each knee Steinman pins were passed from anterior to posterior, 5 cm proximal to the level of the femoral articular cartilage, directly AP and angled at 30 degrees passing medially or laterally. All pins that were passed directly from anterior to posterior and from lateral to medial passed within 5 mm of a major neurovascular structure, while 62.5% of pins passing from medial to lateral passed within 5 mm of a major neurovascular structure. The popliteal vessels and the sciatic nerve are at risk of injury from a navigation pin or drill placed in the distal femur during knee navigation. Caution should be exercised in passing these pins and alternate methods of fixing femoral sensors should be considered.

Entities:  

Mesh:

Year:  2004        PMID: 16112976     DOI: 10.3109/10929080500163547

Source DB:  PubMed          Journal:  Comput Aided Surg        ISSN: 1092-9088


  4 in total

Review 1.  Computer-assisted total knee arthroplasty is currently of no proven clinical benefit: a systematic review.

Authors:  R Stephen J Burnett; Robert L Barrack
Journal:  Clin Orthop Relat Res       Date:  2013-01       Impact factor: 4.176

2.  Case report : femoral shaft fracture resulting from femoral tracker placement in navigated TKA.

Authors:  Peter Bonutti; Daniel Dethmers; James B Stiehl
Journal:  Clin Orthop Relat Res       Date:  2008-02-09       Impact factor: 4.176

3.  Do bicortical diaphyseal array pins create the risk of periprosthetic fracture in robotic-assisted knee arthroplasties?

Authors:  Andrew G Yun; Marilena Qutami; Kory B Dylan Pasko
Journal:  Arthroplasty       Date:  2021-07-05

4.  Pros and cons of navigated versus conventional total knee arthroplasty-a retrospective analysis of over 2400 patients.

Authors:  Matthias Meyer; Tobias Renkawitz; Florian Völlner; Achim Benditz; Joachim Grifka; Markus Weber
Journal:  Arch Orthop Trauma Surg       Date:  2021-02-23       Impact factor: 3.067

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.