Literature DB >> 16111686

Multiphase hemodynamic simulation of pulsatile flow in a coronary artery.

Jonghwun Jung1, Robert W Lyczkowski, Chandrakant B Panchal, Ahmed Hassanein.   

Abstract

A multiphase transient non-Newtonian three-dimensional (3-D) computational fluid dynamics (CFD) simulation has been performed for pulsatile hemodynamics in an idealized curved section of a human coronary artery. We present the first prediction, to the authors' knowledge, of particulate buildup on the inside curvature using the multiphase theory of dense suspension hemodynamics. In this study, the particulates are red blood cells (RBCs). The location of RBC buildup on the inside curvature correlates with lower wall shear stress (WSS) relative to the outside curvature. These predictions provide insight into how blood-borne particulates interact with artery walls and hence, have relevance for understanding atherogenesis since clinical observations show that atherosclerotic plaques generally form on the inside curvatures of arteries. The buildup of RBCs on the inside curvature is driven by the secondary flow and higher residence times. The higher viscosity in the central portion of the curved vessel tends to block their flow, causing them to migrate preferentially through the boundary layer. The reason for this is the nearly neutrally buoyant nature of the dense two-phase hemodynamic flow. The two-phase non-Newtonian viscosity model predicts greater shear thinning than the single-phase non-Newtonian model. Consequently, the secondary flow induced in the curvature is weaker. The waveforms for computed hemodynamic parameters, such as hematocrit, WSS, and viscosity, follow the prescribed inlet velocity waveforms. The lower oscillatory WSS produced on the inside curvature has implications for understanding thickening of the intimal layer.

Entities:  

Mesh:

Year:  2005        PMID: 16111686     DOI: 10.1016/j.jbiomech.2005.06.023

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  15 in total

1.  Effects of stent sizing on endothelial and vessel wall stress: potential mechanisms for in-stent restenosis.

Authors:  Henry Y Chen; James Hermiller; Anjan K Sinha; Michael Sturek; Luoding Zhu; Ghassan S Kassab
Journal:  J Appl Physiol (1985)       Date:  2009-03-19

2.  Computational analysis of the effectiveness of blood flushing with saline injection from an intravascular diagnostic catheter.

Authors:  Narugopal Ghata; Ralph C Aldredge; Julien Bec; Laura Marcu
Journal:  Int J Numer Method Biomed Eng       Date:  2014-07-17       Impact factor: 2.747

Review 3.  Computational Fluid Dynamics and Additive Manufacturing to Diagnose and Treat Cardiovascular Disease.

Authors:  Amanda Randles; David H Frakes; Jane A Leopold
Journal:  Trends Biotechnol       Date:  2017-09-21       Impact factor: 19.536

4.  A computational simulation of the effect of hemodilution on oxygen transport in middle cerebral artery vasospasm.

Authors:  Prashant Chittiboina; Bharat Guthikonda; Christian Wollblad; Steven A Conrad
Journal:  J Cereb Blood Flow Metab       Date:  2011-06-01       Impact factor: 6.200

Review 5.  Mechanobiology and the microcirculation: cellular, nuclear and fluid mechanics.

Authors:  Kris Noel Dahl; Agnieszka Kalinowski; Kerem Pekkan
Journal:  Microcirculation       Date:  2010-04       Impact factor: 2.628

6.  Accounting for residence-time in blood rheology models: do we really need non-Newtonian blood flow modelling in large arteries?

Authors:  Amirhossein Arzani
Journal:  J R Soc Interface       Date:  2018-09-26       Impact factor: 4.118

7.  An extended convection diffusion model for red blood cell-enhanced transport of thrombocytes and leukocytes.

Authors:  S J Hund; J F Antaki
Journal:  Phys Med Biol       Date:  2009-10-07       Impact factor: 3.609

8.  IVUS validation of patient coronary artery lumen area obtained from CT images.

Authors:  Tong Luo; Thomas Wischgoll; Bon Kwon Koo; Yunlong Huo; Ghassan S Kassab
Journal:  PLoS One       Date:  2014-01-29       Impact factor: 3.240

9.  Numerical simulation on the effects of drug eluting stents at different Reynolds numbers on hemodynamic and drug concentration distribution.

Authors:  Yu Chen; Yan Xiong; Wentao Jiang; Fei Yan; Meng Guo; Qingyuan Wang; Yubo Fan
Journal:  Biomed Eng Online       Date:  2015-01-09       Impact factor: 2.819

10.  Coronary CT angiography-based estimation of myocardial perfusion territories for coronary artery FFR and wall shear stress simulation.

Authors:  Yu-Fang Hsieh; Chih-Kuo Lee; Weichung Wang; Yu-Cheng Huang; Wen-Jeng Lee; Tzung-Dau Wang; Cheng-Ying Chou
Journal:  Sci Rep       Date:  2021-07-05       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.