Intermittent myopic shift of 4.0 diopters after implantation of an Artisan iris-supported phakic intraocular lens.

Thomas Kohnen1, Magdalena Cichocki, Jens Bühren, Martin Baumeister.   

Abstract

A 45-year-old man with bilateral high myopia and myopic astigmatism had uneventful implantation of a -10.5 diopters (D) Artisan iris-fixated anterior chamber phakic intraocular lens (PIOL) (Ophtec) in both eyes. In the first days after surgery, uncorrected visual acuity (UCVA) was 20/16 in the right eye and 20/16 in the left; the position of the PIOL was stable. Ten days after surgery, the left eye developed a myopic shift of 4.0 D. Further examination showed that the myopia disappeared when the pupil was medically dilated. After the pupil returned to a natural position, the myopic shift reappeared. Because there were no changes in the subsequent 4 months, we decided to exclavate the IOL, rotate it by 10 degrees, and reenclavate it with less tissue. The myopic shift did not return over the following 20 months, and the UCVA was 20/20. In rare cases, iris-fixated anterior chamber IOLs may induce refractive changes related to effects on the surrounding anatomic structures. This may be corrected by phakic IOL rotation or reenclavation of the phakic IOL with less tissue.

Entities:  

Mesh:

Year:  2005        PMID: 16105622     DOI: 10.1016/j.jcrs.2004.11.056

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  1 in total

1.  [Transient visual deterioration by exposure to cold, phacic anterior chamber lens and forme fruste keratoconus. How can this be explained?].

Authors:  E-M Faschinger; C Faschinger
Journal:  Ophthalmologe       Date:  2014-03       Impact factor: 1.059

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.