Literature DB >> 16104980

Effect of customization of master gutta-percha cone on apical control of root filling using different techniques: an ex vivo study.

S P van Zyl1, K Gulabivala, Y-L Ng.   

Abstract

AIMS: (i) To compare the prevalence of extrusion of root filling material when placed using different root filling techniques, with or without customization of the master gutta-percha (GP) cone; and (ii) to investigate the effects of some factors influencing root filling extrusion and presence of voids.
METHODOLOGY: A total of 180 roots were selected, prepared and randomly allocated to three groups. Five general dental practitioners performed the root fillings; each filled one group of roots (n = 60) using each of three techniques; 'cold lateral compaction' (n = 20), 'warm vertical compaction' (n = 20) and 'continuous-wave' (n = 20) techniques. For each obturation technique, the master GP cone was customized using chloroform in 10 samples. Two groups of the roots were recycled to allow all five operators to fulfill their remit. Two observers, blind to operator and obturation technique, examined the radiographs (master apical file, post-obturation) to determine the presence of root filling extrusion and voids within the apical 5 mm, independently. Root filling extrusion was also confirmed by direct inspection of the root apex after obturation. The data were analysed using logistic regression models.
RESULTS: A total of 300 root fillings were performed; nine were excluded from the analysis. Most of the root fillings (80%, n = 233) were placed within 0.5 mm of the working length; only 20% (n = 58) were placed >0.5 mm beyond the working length. The odds of prevalence of extrusion (>0.5 mm) were significantly reduced by about 50% when cold lateral compaction or customization of GP were used. One operator produced 2.5 times more extruded root fillings than others. Curvature & length of root canal, apical size of prepared canal, as well as operator's preferred obturation technique had no significant influence on the prevalence of extrusion. Customization of GP was the sole factor to significantly reduce the prevalence of voids within the apical 5 mm of working length.
CONCLUSIONS: Root filling extrusion was significantly influenced by 'operator' and was reduced by cold lateral compaction and customization of the master cone. Customization of master cone was the only factor that reduced voids apically.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16104980     DOI: 10.1111/j.1365-2591.2005.01005.x

Source DB:  PubMed          Journal:  Int Endod J        ISSN: 0143-2885            Impact factor:   5.264


  4 in total

1.  Photomicrographic evaluation of the apical sealing capacity of three types of gutta-percha master cones: an in vitro study.

Authors:  Luminita Maria Nica; Andreea Didilescu; Darian Rusu; Adrian Bacila; Stefan-Ioan Stratul
Journal:  Odontology       Date:  2011-05-07       Impact factor: 2.634

2.  Efficiency of 2 electronic apex locators on working length determination: A clinical study.

Authors:  Sibel Koçak; Mustafa Murat Koçak; Baran Can Sağlam
Journal:  J Conserv Dent       Date:  2013-05

3.  Questioning the spot light on Hi-tech endodontics.

Authors:  Jojo Kottoor; Denzil Albuquerque
Journal:  Restor Dent Endod       Date:  2015-12-23

4.  Quantification by SIFT-MS of volatile compounds produced by the action of sodium hypochlorite on a model system of infected root canal content.

Authors:  Konstantinos Ioannidis; Sadia Niazi; Sanjukta Deb; Francesco Mannocci; David Smith; Claire Turner
Journal:  PLoS One       Date:  2018-09-10       Impact factor: 3.240

  4 in total