Literature DB >> 16104778

Development of a novel and automated fluorescent immunoassay for the analysis of beta-lactam antibiotics.

Elena Benito-Peña1, María C Moreno-Bondi, Guillermo Orellana, Angel Maquieira, Aart van Amerongen.   

Abstract

An automated immunosensor for the rapid and sensitive analysis of penicillin type beta-lactam antibiotics has been developed and optimized. An immunogen was prepared by coupling the common structure of the penicillanic beta-lactam antibiotics, i.e., 6-aminopenicillanic acid to keyhole limpet hemocyanin. Polyclonal antibodies raised in rabbits after immunization with this conjugate have been applied for the development of a competitive fluoroimmunoassay (FIA), using a novel fluorescent penicillin {[2S,5R,6R]-3,3-dimethyl-7-oxo-6-[(pyren-1ylacetyl)amino]-4-thia-1-azabicyclo[3.2.0]heptane-2-carboxilic acid, PAAP} as the tracer and penicillin G as the reference antibiotic. Protein A/G covalently bound to an azlactone-activated polymeric support was used for the orientated capture of the antibody-antigen immunocomplexes. Upon desorption from the immunosupport, the emission signal generated by the PAAP-Ab complexes is related to the antibiotic concentration in the sample. The 50% binding inhibition concentration of penicillin G standard curves was at 30 ng mL(-)(1) with a detection limit (10% binding inhibition) of 2.4 ng mL(-)(1) and a dynamic range from 6.0 to 191 ng mL(-)(1) (20-80% binding inhibition) penicillin G. The generic nature of the antiserum was shown by good relative cross-reactivities with penicillin type beta-lactam antibiotics such as amoxicillin (50%), ampicillin (47%), and penicillin V (145%) and a lower response to the isoxazolyl penicillins such as oxacillin, cloxacillin, and dicloxacillin. No cross-reactivity was obtained for cephalosporin type beta-lactam antibiotics (cephapirin), cloramphenicol, or fluoroquinolones (enrofloxacin and ciprofloxacin). The total analysis time was 23 min per determination, and the immunoreactor could be reused for more than 200 cycles without significant loss of activity. The immunosensor has been successfully applied to the direct analysis of penicillin G and amoxicillin in spiked influent and effluent sewage treatment plant water samples with excellent recoveries (mean values for penicillin G and amoxicillin, 99 and 105%, respectively). Results displayed by comparative analysis of the immunosensor with a chromatographic procedure for penicillins showed excellent agreement between both methods.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16104778     DOI: 10.1021/jf0511502

Source DB:  PubMed          Journal:  J Agric Food Chem        ISSN: 0021-8561            Impact factor:   5.279


  8 in total

1.  Flow-through immunosensors using antibody-immobilized polymer monoliths.

Authors:  Jikun Liu; Chien-Fu Chen; Chih-Wei Chang; Don L DeVoe
Journal:  Biosens Bioelectron       Date:  2010-06-11       Impact factor: 10.618

2.  Two colorimetric ampicillin sensing schemes based on the interaction of aptamers with gold nanoparticles.

Authors:  Omid Heydari Shayesteh; Raouf Ghavami
Journal:  Mikrochim Acta       Date:  2019-07-01       Impact factor: 5.833

3.  Immunoassay Methods and their Applications in Pharmaceutical Analysis: Basic Methodology and Recent Advances.

Authors:  Ibrahim A Darwish
Journal:  Int J Biomed Sci       Date:  2006-09

4.  Synthesis and characterization of novel 2, 2'-bipyrimidine fluorescent derivative for protein binding.

Authors:  Vikas S Padalkar; Vikas S Patil; N Sekar
Journal:  Chem Cent J       Date:  2011-11-09       Impact factor: 4.215

5.  Comparison between a Direct-Flow SPR Immunosensor for Ampicillin and a Competitive Conventional Amperometric Device: Analytical Features and Possible Applications to Real Samples.

Authors:  Mauro Tomassetti; Giovanni Merola; Elisabetta Martini; Luigi Campanella; Gabriella Sanzò; Gabriele Favero; Franco Mazzei
Journal:  Sensors (Basel)       Date:  2017-04-10       Impact factor: 3.576

6.  Does Beta-lactam Pharmacokinetic Variability in Critically Ill Patients Justify Therapeutic Drug Monitoring? A Systematic Review.

Authors:  Fekade Bruck Sime; Michael S Roberts; Sandra L Peake; Jeffrey Lipman; Jason A Roberts
Journal:  Ann Intensive Care       Date:  2012-07-28       Impact factor: 6.925

Review 7.  Dismantling the bacterial glycocalyx: Chemical tools to probe, perturb, and image bacterial glycans.

Authors:  Phuong Luong; Danielle H Dube
Journal:  Bioorg Med Chem       Date:  2021-06-07       Impact factor: 3.461

8.  A Flow SPR Immunosensor Based on a Sandwich Direct Method.

Authors:  Mauro Tomassetti; Giorgia Conta; Luigi Campanella; Gabriele Favero; Gabriella Sanzò; Franco Mazzei; Riccarda Antiochia
Journal:  Biosensors (Basel)       Date:  2016-05-13
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.