Literature DB >> 16102620

Value of the duplex waveform at the common femoral artery for diagnosing obstructive aortoiliac disease.

Sandra Spronk1, Pieter T den Hoed, Leenoud C W de Jonge, Lukas C van Dijk, Peter M T Pattynama.   

Abstract

PURPOSE: To evaluate the accuracy, predictive value, and observer agreement of the duplex ultrasound waveform at the common femoral artery as a marker of significant aortoiliac disease in a large group of consecutive patients who underwent a diagnostic workup for peripheral arterial disease in a vascular unit.
METHODS: In 191 consecutive patients (381 aortoiliac segments), we classified the duplex ultrasound waveform at the common femoral artery as triphasic, biphasic, sharp monophasic, or poor monophasic. The waveforms were then compared with the findings of magnetic resonance angiography of the aortoiliac segment and peripheral runoff vessels. We calculated the diagnostic accuracy of the duplex waveform for detecting >50% obstructive disease of the aortoiliac segment and determined the observer agreement for classifying the duplex waveforms done by two independent observers.
RESULTS: Magnetic resonance angiography showed obstruction in 152 (39.9%) of 381 aortoiliac segments in 191 patients. The presence of a poor monophasic waveform, encountered in 91 (24.3%) of 375 segments, was a reliable sign of significant aortoiliac disease, with a positive predictive value of 92%. Other waveforms were nondiagnostic for aortoiliac obstructive disease. The sharp monophasic waveform reliably predicted occlusive disease of the superficial femoral artery that was seen in 17 of 23 instances. There was good observer agreement for classifying duplex waveforms (kappa(w)= 0.85; 95% confidence interval, 0.80 to 0.89).
CONCLUSION: The poor monophasic duplex waveform at the common femoral artery is in itself an accurate marker of aortoiliac obstructive disease. Other waveforms are nondiagnostic for aortoiliac disease.

Entities:  

Mesh:

Year:  2005        PMID: 16102620     DOI: 10.1016/j.jvs.2005.04.048

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  12 in total

1.  Do Doppler waveforms at the common femoral artery accurately predict iliac stenosis?

Authors:  S O'Neill; R K George; W D Wallace; P H Blair; A McKinley
Journal:  Ir J Med Sci       Date:  2010-07-27       Impact factor: 1.568

2.  Transduction of Repetitive Mechanical Stimuli by Piezo1 and Piezo2 Ion Channels.

Authors:  Amanda H Lewis; Alisa F Cui; Malcolm F McDonald; Jörg Grandl
Journal:  Cell Rep       Date:  2017-06-20       Impact factor: 9.423

3.  Aortoiliac occlusive disease, a silent syndrome.

Authors:  Sonia Pilar Rodríguez; Felipe Sandoval
Journal:  BMJ Case Rep       Date:  2019-07-15

4.  Discrepancies in Prevalence of Peripheral Arterial Disease between Lower Extremities at Rest and Postexercise.

Authors:  Kevin P Cohoon; Guillaume Mahe; David A Liedl; Thom W Rooke; Paul W Wennberg
Journal:  Int J Angiol       Date:  2017-02-16

5.  Magnetoactive sponges for dynamic control of microfluidic flow patterns in microphysiological systems.

Authors:  Sungmin Hong; Youngmee Jung; Ringo Yen; Hon Fai Chan; Kam W Leong; George A Truskey; Xuanhe Zhao
Journal:  Lab Chip       Date:  2013-12-06       Impact factor: 6.799

6.  Accuracy of Common Femoral Artery Doppler Waveform Analysis in Predicting Haemodynamically Significant Aortoiliac Lesions.

Authors:  Varsha P Rangankar; Kishor B Taori; Rajesh G Mundhada; Atul D Rewatkar
Journal:  J Clin Diagn Res       Date:  2016-02-01

7.  Echocardiographic evaluation of aorto-iliac occlusive disease.

Authors:  Grzegorz Styczynski; Cezary Szmigielski; Anna Kaczynska; Jerzy Leszczynski; Grzegorz Rosinski; Agnieszka Kuch-Wocial
Journal:  Int J Cardiovasc Imaging       Date:  2011-10-19       Impact factor: 2.357

8.  A novel computer-aided diagnostic approach for detecting peripheral arterial disease in patients with diabetes.

Authors:  Eva Elina Buschmann; Lulu Li; Michèle Brix; Andreas Zietzer; Philipp Hillmeister; Andreas Busjahn; Peter Bramlage; Ivo Buschmann
Journal:  PLoS One       Date:  2018-06-21       Impact factor: 3.240

9.  Effectiveness of a multicenter training programme to teach point-of-care vascular ultrasound for the detection of peripheral arterial disease in people with diabetes.

Authors:  Pasha Normahani; Rishi Agrawal; Vasilliki Bravis; Agnieszka Falinska; Linda Bloomfield; Zaheer Mehar; Dawn Gaulton; Alex Sangster; Tracey Arkle; Corinna Gomm; Mohamed Aslam; Nigel J Standfield; Usman Jaffer
Journal:  J Foot Ankle Res       Date:  2018-07-16       Impact factor: 2.303

10.  Inter-rater Reliability of 4-Item Arterial Doppler Waveform Classification System for Description of Arterial Doppler Waveforms.

Authors:  Rui Zhao; Damien Lanéelle; Meiying Gao; Yuwei Fu; Yisha Tong; Robert Scissons; Chaoyang Wen; Guillaume Mahé
Journal:  Front Cardiovasc Med       Date:  2020-10-26
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.