Literature DB >> 16100177

Stroke volume and pulse pressure variation for prediction of fluid responsiveness in patients undergoing off-pump coronary artery bypass grafting.

Christoph K Hofer1, Stefan M Müller, Lukas Furrer, Richard Klaghofer, Michele Genoni, Andreas Zollinger.   

Abstract

STUDY
OBJECTIVES: Stroke volume variation (SVV) and pulse pressure variation (PPV) determined by the PiCCOplus system (Pulsion Medical Systems; Munich, Germany) may be useful dynamic variables in guiding fluid therapy in patients receiving mechanical ventilation. However, with respect to the prediction of volume responsiveness, conflicting results for SVV have been published in cardiac surgery patients. The goal of this study was to reevaluate SVV in predicting volume responsiveness and to compare it with PPV.
DESIGN: Prospective nonrandomized clinical investigation.
SETTING: University-based cardiac surgery. PATIENTS: Forty patients with preserved left ventricular function undergoing elective off-pump coronary artery bypass grafting.
INTERVENTIONS: Volume replacement therapy before surgery. MEASUREMENTS AND
RESULTS: Following induction of anesthesia, before and after volume replacement (6% hydroxyethyl starch solution, 10 mL/kg ideal body weight), hemodynamic measurements of stroke volume index (SVI), SVV, PPV, global end-diastolic volume index (GEDVI), central venous pressure (CVP) and pulmonary capillary wedge pressure (PCWP) were obtained. Also, left ventricular end-diastolic area index (LVEDAI) was assessed by transesophageal echocardiography. Prediction of ventricular performance was tested by calculating the area under the receiver operating characteristic (ROC) curves and by linear regression analysis; p < 0.05 was considered significant. All measured hemodynamic variables except heart rate changed significantly after fluid loading. GEDVI, CVP, PCWP, and LVEDAI increased, whereas SVV and PPV decreased. The best area under the ROC curve (AUC) was found for SVV (AUC = 0.823) and PPV (AUC = 0.808); the AUC for other preload indexes ranged from 0.493 to 0.636. A significant correlation with changes of SVI was observed for SVV (r = 0.606, p < 0.001) and PPV (r = 0.612, p < 0.001) only. SVV and PPV were closely related (r = 0.861, p < 0.001).
CONCLUSIONS: In contrast to standard preload indexes, SVV and PPV, comparably, showed a good performance in predicting fluid responsiveness in patients before off-pump coronary artery bypass grafting.

Entities:  

Mesh:

Year:  2005        PMID: 16100177     DOI: 10.1378/chest.128.2.848

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  59 in total

1.  Assessment of cardiac preload status by pulse pressure variation in patients after anesthesia induction: comparison with central venous pressure and initial distribution volume of glucose.

Authors:  Zhiyong He; Hui Qiao; Wei Zhou; Yun Wang; Zhendong Xu; Xuehua Che; Jun Zhang; Weimin Liang
Journal:  J Anesth       Date:  2011-09-21       Impact factor: 2.078

2.  Intra-Operative Fluid Management in Adult Neurosurgical Patients Undergoing Intracranial Tumour Surgery: Randomised Control Trial Comparing Pulse Pressure Variance (PPV) and Central Venous Pressure (CVP).

Authors:  Shalini Cynthia Sundaram; Serina Ruth Salins; Amar Nandha Kumar; Grace Korula
Journal:  J Clin Diagn Res       Date:  2016-05-01

3.  The effects of vasoactive drugs on pulse pressure and stroke volume variation in postoperative ventilated patients.

Authors:  Mehrnaz Hadian; Donald A Severyn; Michael R Pinsky
Journal:  J Crit Care       Date:  2010-10-30       Impact factor: 3.425

4.  Pulse pressure: more than 100 years of changes in stroke volume.

Authors:  Maurizio Cecconi; Andrew Rhodes
Journal:  Intensive Care Med       Date:  2011-03-05       Impact factor: 17.440

5.  Impact of skin incision on the pleth variability index.

Authors:  Masaharu Takeyama; Akira Matsunaga; Yasuyuki Kakihana; Mina Masuda; Tamotsu Kuniyoshi; Yuichi Kanmura
Journal:  J Clin Monit Comput       Date:  2011-09-18       Impact factor: 2.502

6.  A pilot study of the pleth variability index as an indicator of volume-responsive hypotension in newborn infants during surgery.

Authors:  Soyhan Bagci; Nicole Müller; Andreas Müller; Andreas Heydweiller; Peter Bartmann; Axel R Franz
Journal:  J Anesth       Date:  2012-11-07       Impact factor: 2.078

7.  Vasodilation increases pulse pressure variation, mimicking hypovolemic status in rabbits.

Authors:  Glauco A Westphal; Anderson Roman Gonçalves; Antônio Bedin; Raquel Bissacotti Steglich; Eliezer Silva; Luiz Francisco Poli-de-Figueiredo
Journal:  Clinics (Sao Paulo)       Date:  2010-02       Impact factor: 2.365

8.  Pulse pressure variation and volume responsiveness during acutely increased pulmonary artery pressure: an experimental study.

Authors:  Fritz Daudel; David Tüller; Stefanie Krähenbühl; Stephan M Jakob; Jukka Takala
Journal:  Crit Care       Date:  2010-06-24       Impact factor: 9.097

9.  Global end-diastolic volume acquired by transpulmonary thermodilution depends on age and gender in awake and spontaneously breathing patients.

Authors:  Stefan Wolf; Alexander Riess; Julia F Landscheidt; Christianto B Lumenta; Patrick Friederich; Ludwig Schürer
Journal:  Crit Care       Date:  2009-12-14       Impact factor: 9.097

10.  Changes in stroke volume induced by passive leg raising in spontaneously breathing patients: comparison between echocardiography and Vigileo/FloTrac device.

Authors:  Matthieu Biais; Lionel Vidil; Philippe Sarrabay; Vincent Cottenceau; Philippe Revel; François Sztark
Journal:  Crit Care       Date:  2009-12-07       Impact factor: 9.097

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.