Literature DB >> 16099521

An inter-centre quality assurance network for IMRT verification: results of the ESTRO QUASIMODO project.

Sofie Gillis1, Carlos De Wagter, Joerg Bohsung, Bruce Perrin, Peter Williams, Ben J Mijnheer.   

Abstract

BACKGROUND AND
PURPOSE: IMRT necessitates extension of existing inter-centre quality assurance programs due to its increased complexity. We assessed the feasibility of an inter-centre verification method for different IMRT techniques.
MATERIALS AND METHODS: Eight European radiotherapy institutions of the QUASIMODO network, have designed an IMRT plan for a horseshoe-shaped PTV surrounding a cylindrical OAR in a simplified pelvic phantom. All centres applied common plan objectives but used their own equipment for planning and delivery. They verified the delivery of this plan according to a common protocol with radiographic film and ionisation chamber measurements. The irradiated films, the results of the ionisation chamber measurements and the computed dose distributions were sent to one analysis centre that compared the measured and computed dose distributions with the gamma method and composite dose-area histograms.
RESULTS: 4% (relative to the prescribed dose) and 3mm (distance-to-agreement) were decided feasible gamma criteria. The composite dose-area histograms showed a maximum local deviation of 3.5% in the mean dose of the PTV and 5% in the OAR. Systematic differences could be identified, and in some cases explained.
CONCLUSIONS: This multi-centre dosimetric verification study demonstrated both the feasibility of a multi-centre quality assurance network to evaluate any IMRT planning and delivery system combination, as well as the validity of the methodology involved.

Entities:  

Mesh:

Year:  2005        PMID: 16099521     DOI: 10.1016/j.radonc.2005.06.021

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  12 in total

1.  Toward a better understanding of the gamma index: Investigation of parameters with a surface-based distance method.

Authors:  Heng Li; Lei Dong; Lifei Zhang; James N Yang; Michael T Gillin; X Ronald Zhu
Journal:  Med Phys       Date:  2011-12       Impact factor: 4.071

2.  Automated prediction of dosimetric eligibility of patients with prostate cancer undergoing intensity-modulated radiation therapy using a convolutional neural network.

Authors:  Tomohiro Kajikawa; Noriyuki Kadoya; Kengo Ito; Yoshiki Takayama; Takahito Chiba; Seiji Tomori; Ken Takeda; Keiichi Jingu
Journal:  Radiol Phys Technol       Date:  2018-08-14

3.  Patient-related quality assurance with different combinations of treatment planning systems, techniques, and machines : A multi-institutional survey.

Authors:  Beatrice Steiniger; René Berger; Sabine Eilzer; Christine Kornhuber; Kathleen Lorenz; Torsten Peil; Carsten Reiffenstuhl; Johannes Schilz; Dirk Schröder; Michael Schwedas; Stephanie Pensold; Mathias Walke; Kirsten Weibert; Ulrich Wolf; Tilo Wiezorek
Journal:  Strahlenther Onkol       Date:  2016-11-03       Impact factor: 3.621

4.  Dose calculation with respiration-averaged CT processed from cine CT without a respiratory surrogate.

Authors:  Adam C Riegel; Moiz Ahmad; Xiaojun Sun; Tinsu Pan
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

5.  Intensity-modulated arc therapy with simultaneous integrated boost in the treatment of primary irresectable cervical cancer. Treatment planning, quality control, and clinical implementation.

Authors:  Katrien Vandecasteele; Wilfried De Neve; Werner De Gersem; Louke Delrue; Leen Paelinck; Amin Makar; Valérie Fonteyne; Carlos De Wagter; Geert Villeirs; Gert De Meerleer
Journal:  Strahlenther Onkol       Date:  2009-12       Impact factor: 3.621

6.  Eight years of IMRT quality assurance with ionization chambers and film dosimetry: experience of the Montpellier Comprehensive Cancer Center.

Authors:  Pascal Fenoglietto; Benoit Laliberté; Norbert Aillères; Olivier Riou; Jean-Bernard Dubois; David Azria
Journal:  Radiat Oncol       Date:  2011-07-20       Impact factor: 3.481

7.  A knowledge-based approach to automated planning for hepatocellular carcinoma.

Authors:  Yujie Zhang; Tingting Li; Han Xiao; Weixing Ji; Ming Guo; Zhaochong Zeng; Jianying Zhang
Journal:  J Appl Clin Med Phys       Date:  2017-11-15       Impact factor: 2.102

8.  Acrylonitrile Butadiene Styrene (ABS) plastic based low cost tissue equivalent phantom for verification dosimetry in IMRT.

Authors:  Rajesh Kumar; S D Sharma; Sudesh Deshpande; Yogesh Ghadi; V S Shaiju; H I Amols; Y S Mayya
Journal:  J Appl Clin Med Phys       Date:  2009-12-17       Impact factor: 2.102

9.  Validation of the RapidArc Delivery System Using a Volumetric Phantom as Per Task Group Report 119 of the American Association of Physicists in Medicine.

Authors:  Lalit Kumar; Girigesh Yadav; Vimal Kishore; Manindra Bhushan; Munish Gairola; Deepak Tripathi
Journal:  J Med Phys       Date:  2019 Apr-Jun

10.  A convolutional neural network approach for IMRT dose distribution prediction in prostate cancer patients.

Authors:  Tomohiro Kajikawa; Noriyuki Kadoya; Kengo Ito; Yoshiki Takayama; Takahito Chiba; Seiji Tomori; Hikaru Nemoto; Suguru Dobashi; Ken Takeda; Keiichi Jingu
Journal:  J Radiat Res       Date:  2019-10-23       Impact factor: 2.724

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.