Literature DB >> 16099196

Accuracy evaluation of direct navigation with an isocentric 3D rotational X-ray system.

Everine B van de Kraats1, Theo van Walsum, Lance Kendrick, Niels J Noordhoek, Wiro J Niessen.   

Abstract

Minimally invasive interventions are often performed under fluoroscopic guidance. Drawbacks of fluoroscopic guidance are the fact that the presented images are 2D projections and that both the patient and the clinician are exposed to radiation. Image-guided navigation using pre-interventionally acquired 3D MR or CT data is an alternative. However, this often requires invasive anatomical landmark-based, marker-based or surface-based image-to-patient registration. In this paper, a coupling between an image-guided navigation system and an intraoperative C-arm X-ray device with 3D imaging capabilities (3D rotational X-ray (3DRX) system) that enables direct navigation without invasive image-to-patient registration on 3DRX volumes, is described and evaluated. The coupling is established in a one-time preoperative calibration procedure. The individual steps in the registration procedure are explained and evaluated. The acquired navigation accuracy using this coupling is approximately one millimeter.

Entities:  

Mesh:

Year:  2005        PMID: 16099196     DOI: 10.1016/j.media.2005.04.012

Source DB:  PubMed          Journal:  Med Image Anal        ISSN: 1361-8415            Impact factor:   8.545


  6 in total

1.  An on-board surgical tracking and video augmentation system for C-arm image guidance.

Authors:  S Reaungamornrat; Y Otake; A Uneri; S Schafer; D J Mirota; S Nithiananthan; J W Stayman; G Kleinszig; A J Khanna; R H Taylor; J H Siewerdsen
Journal:  Int J Comput Assist Radiol Surg       Date:  2012-04-27       Impact factor: 2.924

2.  Unilateral C1 Lateral Mass and C2 Pedicle Screw Fixation for Atlantoaxial Instability in Rheumatoid Arthritis Patients: Comparison with the Bilateral Method.

Authors:  Seung-Chull Paik; Hyoung-Joon Chun; Koang Hum Bak; Jeil Ryu; Kyu-Sun Choi
Journal:  J Korean Neurosurg Soc       Date:  2015-06-30

3.  Calibration of RGBD camera and cone-beam CT for 3D intra-operative mixed reality visualization.

Authors:  Sing Chun Lee; Bernhard Fuerst; Javad Fotouhi; Marius Fischer; Greg Osgood; Nassir Navab
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-04-08       Impact factor: 2.924

4.  Co-localized augmented human and X-ray observers in collaborative surgical ecosystem.

Authors:  Javad Fotouhi; Mathias Unberath; Tianyu Song; Jonas Hajek; Sing Chun Lee; Bastian Bier; Andreas Maier; Greg Osgood; Mehran Armand; Nassir Navab
Journal:  Int J Comput Assist Radiol Surg       Date:  2019-07-26       Impact factor: 2.924

5.  Accuracy and Safety in Pedicle Screw Placement in the Thoracic and Lumbar Spines : Comparison Study between Conventional C-Arm Fluoroscopy and Navigation Coupled with O-Arm® Guided Methods.

Authors:  Myung-Hoon Shin; Kyeong-Sik Ryu; Chun-Kun Park
Journal:  J Korean Neurosurg Soc       Date:  2012-09-30

6.  Placement of C2 laminar screws using three-dimensional fluoroscopy-based image guidance by Eric W. Nottmeier and Andrew B. Foy.

Authors:  J J Verlaan
Journal:  Eur Spine J       Date:  2008-01-03       Impact factor: 3.134

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.