Angular position, range of motion and velocity of arm elevation: a study of consistency of performance.

Joan García-Alsina1, Concepción García Almazan, José Moranta Mesquida, Eulogio Pleguezuelos Cobo.   

Abstract

BACKGROUND: To define the normal range, velocity and consistency of the movement of active arm elevation with humerus in neutral or in external rotation using a simplified kinematic model.
METHODS: Nine normal volunteers and the non-involved side of twenty five patients with unilateral shoulder lesion participated. A 3D optoelectronic tracking system was used to register the movement of raising the arm from the normal upright position to maximal elevation in a repetitive way. Peak humeral position, range of movement, velocity of motion and consistency of cycles were analyzed. Descriptive statistics, correlation between variables and with sex, age and side are presented, including differences between performances of movement done in neutral or external rotation.
FINDINGS: Data of the six variables were: maximal abduction 142 degrees [137.4-147.0], range of motion 118.1 degrees [112-124], maximal velocity 238 degrees/s [209-265]; mean velocity 113 degrees/s [96-130]; coefficient of variation of maximal angular abduction was 2.2% [1.7-2.7]; coefficient of variation of maximal velocity 8.6% [7.3-9.9]. No significant differences were observed either on side, sex or between the shoulder of normal volunteers or that of the patients with opposite shoulder lesions. Participants older than 45 years old showed only a significant slightly lower average velocity. The study confirms the weak association between dependent (biomechanical) and independent variables.
INTERPRETATION: As it is described here, analysis of arm elevation has not been previously studied and shows that has a good consistency in angular position, velocity and repeatability of motion in normal conditions which permits a picture of the overall performance of the shoulder.

Entities:  

Mesh:

Year:  2005        PMID: 16098645     DOI: 10.1016/j.clinbiomech.2005.05.005

Source DB:  PubMed          Journal:  Clin Biomech (Bristol, Avon)        ISSN: 0268-0033            Impact factor:   2.063


  1 in total

1.  Restricted upper extremity range of motion in mucopolysaccharidosis type I: no response to one year of enzyme replacement therapy.

Authors:  J Cox-Brinkman; M J C Smeulders; C E M Hollak; F A Wijburg
Journal:  J Inherit Metab Dis       Date:  2006-12-11       Impact factor: 4.982

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.