Literature DB >> 16097648

Preparation, radiochemical purity control and stability of 99mTc-mertiatide (Mag-3).

Formijn J van Hemert1, Henk van Lenthe, Kirsten J M Schimmel, Berthe L F van Eck-Smit.   

Abstract

BACKGROUND: Scintigraphic image analysis of 99mTc-mertiatide (Mag-3, mercaptoacetyltriglycine) clearance provides the determination of the blood flow, the tubular transit time and the excretion as well from both kidneys. Radiopharmaceutical routine recommends a radiochemical purity control before administration of the product to a patient. The main objective of this study is to develop a Mag-3 labeling procedure that fits better than the previous one in our daily routine production of radiopharmaceuticals.
METHODS: Increasing proportions of 99mTc-Mag-3 were measured during the heating and cooling steps of the Mag-3 labeling procedure. HPLC analysis was used to confirm the results of a rapid radiochemical quality control assay on standard ITLC-SG paper.
RESULTS: The reconstitution time takes 20-25 minutes from the harvest of pertechnetate to a ready-for-use calibrated patient syringe. The HPLC profile of 99mTc-Mag-3 including its minor impurities remains unchanged for 24-48 hours after reconstitution.
CONCLUSIONS: The application of a programmable Peltier-directed device for heating/cooling provides a better control of the temperature course. The procedure proposed fully meets the labeling criteria recommended by the supplier and can be performed with a minimum of attention within a time-span that we formerly needed for solely the radiochemical purity control assay. Moreover, 99mTc-Mag-3 prepared in this way seems to be considerably more stable than mentioned in the manufacturer's instructions.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16097648     DOI: 10.1007/bf02984631

Source DB:  PubMed          Journal:  Ann Nucl Med        ISSN: 0914-7187            Impact factor:   2.668


  2 in total

1.  A new two-strip TLC method for the quality control of technetium-99m mercaptoacetyl-triglycine (99mTc-MAG3).

Authors:  Marietta Straub; Michel Leresche; Claude Pilloud; Fabien Devynck; Nicolas Stritt; Rolf Hesselmann
Journal:  EJNMMI Radiopharm Chem       Date:  2018-03-14

2.  Monocyte scintigraphy in rheumatoid arthritis: the dynamics of monocyte migration in immune-mediated inflammatory disease.

Authors:  Rogier M Thurlings; Carla A Wijbrandts; Roelof J Bennink; Serge E Dohmen; Carlijn Voermans; Diana Wouters; Elena S Izmailova; Danielle M Gerlag; Berthe L F van Eck-Smit; Paul P Tak
Journal:  PLoS One       Date:  2009-11-17       Impact factor: 3.240

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.