Literature DB >> 1609084

Meniscal changes in the elderly: correlation of MR imaging and histologic findings.

J Hodler1, P Haghighi, M N Pathria, D Trudell, D Resnick.   

Abstract

In elderly patients, degenerative changes of the meniscus are common and may mimic a tear. The magnetic resonance (MR) image findings of 179 meniscal sections in 20 cadaver knees were correlated with the histologic and gross pathologic findings. The sensitivity of standard T1-weighted spin-echo images and their corresponding meniscal windows in depicting meniscal tears was 80.6%, specificity was 72.4%, and accuracy was 76.7%. These results are not as good as results reported previously. A major difficulty is the occurrence of grade 3 meniscal signal intensity and diffuse intrameniscal signal intensity in torn and intact menisci. MR imaging in elderly patients, however, is still useful in the diagnosis of meniscal abnormalities. Normal low signal intensity depicted within a meniscus at MR imaging and changes in grades 1 and 2 intrameniscal signal intensity are reliable signs of an intact meniscal surface. Grade 3 and diffuse meniscal signal intensities do not allow a specific diagnosis; menisci with these characteristics should be described as degenerated with a high probability of a tear.

Entities:  

Mesh:

Year:  1992        PMID: 1609084     DOI: 10.1148/radiology.184.1.1609084

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  9 in total

1.  Meniscal calcifications: morphologic and quantitative evaluation by using 2D inversion-recovery ultrashort echo time and 3D ultrashort echo time 3.0-T MR imaging techniques--feasibility study.

Authors:  Patrick Omoumi; Won C Bae; Jiang Du; Eric Diaz; Sheronda Statum; Graeme M Bydder; Christine B Chung
Journal:  Radiology       Date:  2012-07       Impact factor: 11.105

2.  Natural History of Intrameniscal Signal Intensity on Knee MR Images: Six Years of Data from the Osteoarthritis Initiative.

Authors:  Jaanika Kumm; Frank W Roemer; Ali Guermazi; Aleksandra Turkiewicz; Martin Englund
Journal:  Radiology       Date:  2015-07-14       Impact factor: 11.105

Review 3.  Conventional and ultrashort time-to-echo magnetic resonance imaging of articular cartilage, meniscus, and intervertebral disk.

Authors:  Won C Bae; Jiang Du; Graeme M Bydder; Christine B Chung
Journal:  Top Magn Reson Imaging       Date:  2010-10

Review 4.  The diagnostic performance of MRI in osteoarthritis: a systematic review and meta-analysis.

Authors:  L Menashe; K Hirko; E Losina; M Kloppenburg; W Zhang; L Li; D J Hunter
Journal:  Osteoarthritis Cartilage       Date:  2011-10-19       Impact factor: 6.576

5.  Two simple stitches for medial meniscus posterior root repair prevents the progression of meniscal extrusion and reduces intrameniscal signal intensity better than modified Mason-Allen sutures.

Authors:  Yuki Okazaki; Takayuki Furumatsu; Takaaki Hiranaka; Yuya Kodama; Yusuke Kamatsuki; Keisuke Kintaka; Toshifumi Ozaki
Journal:  Eur J Orthop Surg Traumatol       Date:  2020-11-21

6.  Comparison of clinical, MRI and arthroscopic assessments of chronic ACL injuries, meniscal tears and cartilage defects.

Authors:  L Felli; G Garlaschi; A Muda; A Tagliafico; M Formica; A Zanirato; M Alessio-Mazzola
Journal:  Musculoskelet Surg       Date:  2016-09-14

7.  Correlation of histological examination of meniscus with MR images: focused on high signal intensity of the meniscus not caused by definite meniscal tear and impact on mr diagnosis of tears.

Authors:  Chun Ai Li; Min Ki Kim; In Hwan Kim; Ju Hong Lee; Kyu Yun Jang; Sang Yong Lee
Journal:  Korean J Radiol       Date:  2013-11-05       Impact factor: 3.500

8.  Accuracy of magnetic resonance imaging of the knee in the community setting.

Authors:  Jolene C Hardy; Gregory T Evangelista; William A Grana; Robert E Hunter
Journal:  Sports Health       Date:  2012-05       Impact factor: 3.843

9.  Biomechanics of the medial meniscus in the osteoarthritic knee joint.

Authors:  Karol Daszkiewicz; Piotr Łuczkiewicz
Journal:  PeerJ       Date:  2021-11-24       Impact factor: 2.984

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.