Literature DB >> 16087097

CAD-aided mammogram training.

Ping Luo1, Wei Qian, Pat Romilly.   

Abstract

RATIONALE AND
OBJECTIVES: Although computer-aided detection (CAD) improves the diagnosis rate of early breast cancer, it has not been well integrated into radiology residency and technician training program. Moreover, CAD performance studies ignore the reader's training and experience with CAD. The purpose of this study was to investigate whether CAD training via a cognitive-perceptual based hypermedia program has effects on the performance studies of mammogram reading.
MATERIALS AND METHODS: Three observers read a pretest set of 80 breast cancer cases (43 negative, 23 benign, and 14 malignant cancer cases). During 4 weeks' training, the observers used a hypermedia instructional program in CAD-aided mammography interpretation. The program includes modules of CAD attention-focusing schemes, CAD procedural knowledge, and case-based simulations in mammography interpretation in consensus with CAD. By the end of the fourth week of the training, they reviewed a posttest set of cases. Data were analyzed with multireader, multicase receiver operating characteristic methods.
RESULTS: Three readers performed better in mammogram reading after training in CAD knowledge than they did before CAD training. CAD training and experience improved the performance of CAD-aided mammography interpretation.
CONCLUSION: A statistically significant difference was found in each observer's performance in CAD-aided mammogram reading before and after the training. CAD training will influence the perception, recognition, and interpretation of early breast cancer and CAD performance studies. Furthermore, the young generation of radiologic professionals can have more training in various attention-focusing features, declarative knowledge, procedural knowledge, and conditional knowledge of CAD and incorporate them into their knowledge base and strategic processing for the purpose of improving the accuracy of mammography interpretation performance.

Entities:  

Mesh:

Year:  2005        PMID: 16087097     DOI: 10.1016/j.acra.2005.04.011

Source DB:  PubMed          Journal:  Acad Radiol        ISSN: 1076-6332            Impact factor:   3.173


  7 in total

1.  False positive marks on unsuspicious screening mammography with computer-aided detection.

Authors:  Mary C Mahoney; Karthikeyan Meganathan
Journal:  J Digit Imaging       Date:  2011-10       Impact factor: 4.056

2.  Use of Standardized Uptake Value Ratios Decreases Interreader Variability of [18F] Florbetapir PET Brain Scan Interpretation.

Authors:  A P Nayate; J G Dubroff; J E Schmitt; I Nasrallah; R Kishore; D Mankoff; D A Pryma
Journal:  AJNR Am J Neuroradiol       Date:  2015-03-12       Impact factor: 3.825

3.  Impact of computer-aided detection systems on radiologist accuracy with digital mammography.

Authors:  Elodia B Cole; Zheng Zhang; Helga S Marques; R Edward Hendrick; Martin J Yaffe; Etta D Pisano
Journal:  AJR Am J Roentgenol       Date:  2014-10       Impact factor: 3.959

Review 4.  Is single reading with computer-aided detection (CAD) as good as double reading in mammography screening? A systematic review.

Authors:  Edward Azavedo; Sophia Zackrisson; Ingegerd Mejàre; Marianne Heibert Arnlind
Journal:  BMC Med Imaging       Date:  2012-07-24       Impact factor: 1.930

5.  Computer-aided detection of breast cancer - have all bases been covered?

Authors:  Gautam S Muralidhar; Tamara Miner Haygood; Tanya W Stephens; Gary J Whitman; Alan C Bovik; Mia K Markey
Journal:  Breast Cancer (Auckl)       Date:  2008-05-23

6.  Observer training for computer-aided detection of pulmonary nodules in chest radiography.

Authors:  Diederick W De Boo; François van Hoorn; Joost van Schuppen; Laura Schijf; Maeke J Scheerder; Nicole J Freling; Onno Mets; Michael Weber; Cornelia M Schaefer-Prokop
Journal:  Eur Radiol       Date:  2012-03-25       Impact factor: 5.315

7.  CAD May Not be Necessary for Microcalcifications in the Digital era, CAD May Benefit Radiologists for Masses.

Authors:  Stamatia V Destounis; Andrea L Arieno; Renee C Morgan
Journal:  J Clin Imaging Sci       Date:  2012-07-28
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.