Literature DB >> 16087093

Accuracy of computed tomography attenuation values in the characterization of pleural fluid: an ROC study.

Kiran R Nandalur1, Andrew H Hardie, Sirisha R Bollampally, Jaywant P Parmar, Klaus D Hagspiel.   

Abstract

RATIONALE AND
OBJECTIVES: To assess the accuracy of computed tomography (CT) in characterizing pleural fluid based on attenuation values.
MATERIALS AND METHODS: Protocol was approved by the local institutional review board and informed consent was waived. We retrospectively analyzed 145 pleural effusions of 145 patients (mean/standard deviation age: 60.7/15.9 years; 69 females) who underwent CT of the thorax and diagnostic thoracentesis within 7 days of each other. Effusions were classified as transudates or exudates using laboratory markers based on Light's criteria. The mean Hounsfield units (HU) of an effusion was determined by a region of interest on the three slices with the greatest anteroposterior diameter. A receiver operating characteristic curve was constructed to determine threshold values for classification on the basis of mean HU and to examine overall accuracy, using the area under the curve (A(z)).
RESULTS: Of the 101 exudates and 44 transudates, the mean attenuation of exudates (17.1 HU/standard deviation 4.4) was significantly higher than transudates (12.5 HU/6.3), (P < .001). There was a modest but significant positive relationship between mean HU and laboratory markers, with the strongest relationship with pleural/serum protein (r = 0.57, P < .001) and total pleural protein (r = 0.56, P < .001). The overall accuracy of attenuation values for identifying exudates was moderate, Az = 0.775, standard error = 0.039, with the largest limitation being the overlap with transudates in the 10-20 HU range, which constituted 66% (90/145) of the total effusions measured.
CONCLUSION: Although the mean attenuation of exudates is significantly higher than transudates, the clinical use of CT numbers to characterize pleural fluid is not recommended, as their accuracy is only moderate. Moreover, there is a notable overlap in attenuation values between transudates and exudates for a majority of effusions.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16087093     DOI: 10.1016/j.acra.2005.05.002

Source DB:  PubMed          Journal:  Acad Radiol        ISSN: 1076-6332            Impact factor:   3.173


  12 in total

1.  Computed tomography attenuation values of ascites are helpful to predict perforation site.

Authors:  Ryo Seishima; Koji Okabayashi; Hirotoshi Hasegawa; Masashi Tsuruta; Hiroki Hoshino; Toru Yamada; Yuko Kitagawa
Journal:  World J Gastroenterol       Date:  2015-02-07       Impact factor: 5.742

2.  A generic approach to pathological lung segmentation.

Authors:  Awais Mansoor; Ulas Bagci; Ziyue Xu; Brent Foster; Kenneth N Olivier; Jason M Elinoff; Anthony F Suffredini; Jayaram K Udupa; Daniel J Mollura
Journal:  IEEE Trans Med Imaging       Date:  2014-07-08       Impact factor: 10.048

3.  Characterization of mesothelioma and tissues present in contrast-enhanced thoracic CT scans.

Authors:  Neal Corson; William F Sensakovic; Christopher Straus; Adam Starkey; Samuel G Armato
Journal:  Med Phys       Date:  2011-02       Impact factor: 4.071

4.  Computed tomographic measurement of canine urine concentration.

Authors:  Allison L Zwingenberger; Danielle D Carrade Holt
Journal:  Can Vet J       Date:  2017-02       Impact factor: 1.008

Review 5.  Hemopericardium in the acute clinical setting: Are we ready for a tailored management approach on the basis of MDCT findings?

Authors:  Tullio Valente; Maria Pignatiello; Giacomo Sica; Giorgio Bocchini; Gaetano Rea; Salvatore Cappabianca; Mariano Scaglione
Journal:  Radiol Med       Date:  2020-11-02       Impact factor: 3.469

6.  Computerized tomography attenuation values can be used to differentiate hydronephrosis from pyonephrosis.

Authors:  Emrah Yuruk; Murat Tuken; Suhejb Sulejman; Aykut Colakerol; Ege Can Serefoglu; Kemal Sarica; Ahmet Yaser Muslumanoglu
Journal:  World J Urol       Date:  2016-07-01       Impact factor: 4.226

7.  Efficacy of CT in diagnosis of transudates and exudates in patients with pleural effusion.

Authors:  Neşat Çullu; Serdar Kalemci; Ömer Karakaş; İrfan Eser; Funda Yalçin; Fatıma Nurefşan Boyacı; Ekrem Karakaş
Journal:  Diagn Interv Radiol       Date:  2014 Mar-Apr       Impact factor: 2.630

8.  Effectiveness of computed tomography attenuation values in characterization of pericardial effusion.

Authors:  Mehmet Serkan Çetin; Elif Hande Özcan Çetin; Mustafa Özdemir; Serkan Topaloğlu; Dursun Aras; Ahmet Temizhan; Sinan Aydoğdu
Journal:  Anatol J Cardiol       Date:  2017-01-17       Impact factor: 1.596

9.  Efficacy of Computed Tomography (CT) Attenuation Values and CT Findings in the Differentiation of Pleural Effusion.

Authors:  Kadihan Yalçin-Şafak; Neslihan Umarusman-Tanju; Muhammet Ayyıldız; Nihal Yücel; Tamer Baysal
Journal:  Pol J Radiol       Date:  2017-02-19

10.  Differential diagnosis between benign and malignant pleural effusion with dual-energy spectral CT.

Authors:  Xirong Zhang; Haifeng Duan; Yong Yu; Chunling Ma; Zhanli Ren; Yuxin Lei; Taiping He; Ming Zhang
Journal:  PLoS One       Date:  2018-04-11       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.