Literature DB >> 16086314

Continuous ASL (CASL) perfusion MRI with an array coil and parallel imaging at 3T.

Ze Wang1, Jiongjiong Wang, Thomas J Connick, Gabriel S Wetmore, John A Detre.   

Abstract

The purpose of this work was to assess the feasibility and efficacy of using an array coil and parallel imaging in continuous arterial spin labeling (CASL) perfusion MRI. An 8-channel receive-only array head coil was used in conjunction with a surrounding detunable volume transmit coil. The signal to noise ratio (SNR), temporal stability, cerebral blood flow (CBF), and perfusion image coverage were measured from steady state CASL scans using: a standard volume coil, array coil, and array coil with 2- and 3-fold accelerated parallel imaging. Compared to the standard volume coil, the array coil provided 3 times the average SNR increase and higher temporal stability for the perfusion weighted images, even with threefold acceleration. Although perfusion images of the array coil were affected by the inhomogeneous coil sensitivities, this effect was invisible in the quantitative CBF images, which showed highly reproducible perfusion values compared to the standard volume coil. The unfolding distortions of parallel imaging were suppressed in the perfusion images by pairwise subtraction, though they sharply degraded the raw EPI images. Moreover, parallel imaging provided the potential of acquiring more slices due to the shortened acquisition time and improved coverage in brain regions with high static field inhomogeneity. Such results highlight the potential utility of array coils and parallel imaging in ASL perfusion MRI. Copyright (c) 2005 Wiley-Liss, Inc.

Mesh:

Substances:

Year:  2005        PMID: 16086314     DOI: 10.1002/mrm.20574

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  30 in total

1.  Exploring the after-effects of theta burst magnetic stimulation on the human motor cortex: a functional imaging study.

Authors:  Lizbeth Cárdenas-Morales; Georg Grön; Thomas Kammer
Journal:  Hum Brain Mapp       Date:  2010-12-22       Impact factor: 5.038

2.  Nonlinear magnetic field gradients can reduce SAR in flow-driven arterial spin labeling measurements.

Authors:  Kenneth I Marro; Donghoon Lee; Outi M Hyyti
Journal:  J Magn Reson       Date:  2006-12-18       Impact factor: 2.229

3.  Multi-site exploration of sex differences in brain reactivity to smoking cues: Consensus across sites and methodologies.

Authors:  Kelly M Dumais; Teresa R Franklin; Kanchana Jagannathan; Nathan Hager; Michael Gawrysiak; Jennifer Betts; Stacey Farmer; Emily Guthier; Heather Pater; Amy C Janes; Reagan R Wetherill
Journal:  Drug Alcohol Depend       Date:  2017-07-08       Impact factor: 4.492

4.  An investigation of statistical power for continuous arterial spin labeling imaging at 1.5 T.

Authors:  Iris Asllani; Ajna Borogovac; Clinton Wright; Ralph Sacco; Truman R Brown; Eric Zarahn
Journal:  Neuroimage       Date:  2007-10-24       Impact factor: 6.556

5.  Multivariate and univariate analysis of continuous arterial spin labeling perfusion MRI in Alzheimer's disease.

Authors:  Iris Asllani; Christian Habeck; Nikolaos Scarmeas; Ajna Borogovac; Truman R Brown; Yaakov Stern
Journal:  J Cereb Blood Flow Metab       Date:  2007-10-24       Impact factor: 6.200

Review 6.  Clinical neuroimaging using arterial spin-labeled perfusion magnetic resonance imaging.

Authors:  Ronald L Wolf; John A Detre
Journal:  Neurotherapeutics       Date:  2007-07       Impact factor: 7.620

7.  Mapping resting-state functional connectivity using perfusion MRI.

Authors:  Kai-Hsiang Chuang; Peter van Gelderen; Hellmut Merkle; Jerzy Bodurka; Vasiliki N Ikonomidou; Alan P Koretsky; Jeff H Duyn; S Lalith Talagala
Journal:  Neuroimage       Date:  2008-01-17       Impact factor: 6.556

8.  Assessment of functional development in normal infant brain using arterial spin labeled perfusion MRI.

Authors:  Ze Wang; María Fernández-Seara; David C Alsop; Wen-Ching Liu; Judy F Flax; April A Benasich; John A Detre
Journal:  Neuroimage       Date:  2007-10-05       Impact factor: 6.556

Review 9.  Perfusion MRI: the five most frequently asked technical questions.

Authors:  Marco Essig; Mark S Shiroishi; Thanh Binh Nguyen; Marc Saake; James M Provenzale; David Enterline; Nicoletta Anzalone; Arnd Dörfler; Alex Rovira; Max Wintermark; Meng Law
Journal:  AJR Am J Roentgenol       Date:  2013-01       Impact factor: 3.959

10.  Parkinson's disease spatial covariance pattern: noninvasive quantification with perfusion MRI.

Authors:  Yilong Ma; Chaorui Huang; Jonathan P Dyke; Hong Pan; David Alsop; Andrew Feigin; David Eidelberg
Journal:  J Cereb Blood Flow Metab       Date:  2010-01-06       Impact factor: 6.200

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.