Literature DB >> 16085097

Absolute measurement of ultrasonic backscatter from single microbubbles.

Vassilis Sboros1, Stepher D Pye, Calum A Macdonald, Jaganathan Gomatam, Carmel M Moran, William N McDicken.   

Abstract

Good quality acoustical experiments are needed to measure microbubble behavior. An absolute calibration of the transmitted ultrasound field is possible using a calibrated hydrophone, but characterization of the received ultrasound beam is a more elaborate process and is not described in the literature. A new system based on a hydrodynamically focused flow has been used to measure echoes from single microbubbles at well specified positions in the ultrasonic field. An experimental set-up was built around a commercial scanner (Sonos 5500, Philips Medical Systems) to measure the scatter from solid spheres with radii between 30 to 60 microm. The behavior of these linear scatterers is accurately predicted by theory and software was produced to incorporate a simulation of the experimental conditions. The calibration of a phased array transducer was achieved by quantifying the receiver's spectral sensitivity for the range of receive frequencies (1.2 to 4.5 MHz). Examples of echoes from the microbubble agent Definity are used to illustrate the implementation of the calibration technique.

Mesh:

Substances:

Year:  2005        PMID: 16085097     DOI: 10.1016/j.ultrasmedbio.2005.04.018

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  6 in total

1.  Accuracy of a bistatic scattering substitution technique for calibration of focused receivers.

Authors:  Kyle T Rich; T Douglas Mast
Journal:  J Acoust Soc Am       Date:  2015-11       Impact factor: 1.840

2.  Observation of contrast agent response to chirp insonation with a simultaneous optical-acoustical system.

Authors:  Yang Sun; Shukui Zhao; Paul A Dayton; Katherine W Ferrara
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2006-06       Impact factor: 2.725

Review 3.  For Whom the Bubble Grows: Physical Principles of Bubble Nucleation and Dynamics in Histotripsy Ultrasound Therapy.

Authors:  Kenneth B Bader; Eli Vlaisavljevich; Adam D Maxwell
Journal:  Ultrasound Med Biol       Date:  2019-03-26       Impact factor: 2.998

4.  Encapsulated microbubbles and echogenic liposomes for contrast ultrasound imaging and targeted drug delivery.

Authors:  Shirshendu Paul; Rahul Nahire; Sanku Mallik; Kausik Sarkar
Journal:  Comput Mech       Date:  2014-03       Impact factor: 4.014

5.  Enhanced microbubble contrast agent oscillation following 250 kHz insonation.

Authors:  Tali Ilovitsh; Asaf Ilovitsh; Josquin Foiret; Charles F Caskey; Jiro Kusunose; Brett Z Fite; Hua Zhang; Lisa M Mahakian; Sarah Tam; Kim Butts-Pauly; Shengping Qin; Katherine W Ferrara
Journal:  Sci Rep       Date:  2018-11-05       Impact factor: 4.379

6.  Super-Resolution Contrast-Enhanced Ultrasound Methodology for the Identification of In Vivo Vascular Dynamics in 2D.

Authors:  Evangelos Kanoulas; Mairead Butler; Caitlin Rowley; Vasiliki Voulgaridou; Konstantinos Diamantis; William Colin Duncan; Alan McNeilly; Michalakis Averkiou; Hessel Wijkstra; Massimo Mischi; Rhodri Simon Wilson; Weiping Lu; Vassilis Sboros
Journal:  Invest Radiol       Date:  2019-08       Impact factor: 6.016

  6 in total