Literature DB >> 16084328

Improved semiautomated quantification of left ventricular volumes and ejection fraction using 3-dimensional echocardiography with a full matrix-array transducer: comparison with magnetic resonance imaging.

Enrico G Caiani1, Cristiana Corsi, Jose Zamorano, Lissa Sugeng, Peter MacEneaney, Lynn Weinert, Roberto Battani, Juan Luis Gutiérrez-Chico, Juan Luis Gutierrez, Rick Koch, Leopoldo Perez de Isla, Victor Mor-Avi, Roberto M Lang.   

Abstract

Our goals were to: (1) develop a technique for 3-dimensional (3D) direct, model-independent quantitative assessment of left ventricular (LV) volume and ejection fraction based on semiautomated detection of LV endocardial surface from transthoracic near real-time full matrix-array 3D echocardiographic (FM3DE) imaging; (2) evaluate the accuracy of LV volumes obtained with this technique, using cardiac magnetic resonance imaging (MRI) measurements as the reference for comparison; and (3) determine the effects of contrast enhancement on the accuracy of FM3DE measurements. A total of 46 patients underwent 2-dimensional echocardiography, FM3DE, and cardiac MRI. End-diastolic volume, end-systolic volume, and ejection fraction were derived from endocardial borders manually traced from 2-dimensional echocardiographic images and from semiautomatically detected LV cavity from FM3DE data. In 14 patients, FM3DE was also acquired with contrast. All measurements were compared with MRI values using linear regression and Bland-Altman analyses. FM3DE was feasible in 44 of 46 patients with LV volumes < 345 mL. LV volumes and ejection fraction computed from FM3DE resulted in higher levels of agreement with MRI than conventional 2-dimensional echocardiography, with lower interobserver variability. With contrast enhancement, FM3DE significantly underestimated LV volumes and showed increased interobserver variability. Semiautomated LV endocardial surface detection from FM3DE images is feasible and results in fast and accurate assessment of LV function.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16084328     DOI: 10.1016/j.echo.2004.12.015

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  21 in total

Review 1.  Three-Dimensional Echocardiography: Current Status and Real-Life Applications.

Authors:  Victor Chien-Chia Wu; Masaaki Takeuchi
Journal:  Acta Cardiol Sin       Date:  2017-03       Impact factor: 2.672

2.  Quantification of left ventricular volume and global function using a fast automated segmentation tool: validation in a clinical setting.

Authors:  Daniel Barbosa; Brecht Heyde; Thomas Dietenbeck; Helene Houle; Denis Friboulet; Olivier Bernard; Jan D'hooge
Journal:  Int J Cardiovasc Imaging       Date:  2012-08-01       Impact factor: 2.357

Review 3.  Intraoperative cardiac assessment with transesophageal echocardiography for decision-making in cardiac anesthesia.

Authors:  Koichi Akiyama; Shoji Arisawa; Masahiro Ide; Masaaki Iwaya; Yoshiyuki Naito
Journal:  Gen Thorac Cardiovasc Surg       Date:  2013-02-13

Review 4.  Assessment and treatment of right ventricular failure.

Authors:  Marc A Simon
Journal:  Nat Rev Cardiol       Date:  2013-02-12       Impact factor: 32.419

5.  Three-dimensional echocardiography: a new paradigm shift.

Authors:  Jun Kwan
Journal:  J Echocardiogr       Date:  2013-08-06

6.  Three-dimensional echocardiography in various types of heart disease: a comparison study of magnetic resonance imaging and 64-slice computed tomography in a real-world population.

Authors:  Angelo Squeri; Stefano Censi; Claudio Reverberi; Nicola Gaibazzi; Marco Baldelli; Simone Maurizio Binno; Enrico Properzi; Stefano Bosi
Journal:  J Echocardiogr       Date:  2016-09-02

7.  Current clinical applications of transthoracic three-dimensional echocardiography.

Authors:  Luigi P Badano; Francesca Boccalini; Denisa Muraru; Lucia Dal Bianco; Diletta Peluso; Roberto Bellu; Giacomo Zoppellaro; Sabino Iliceto
Journal:  J Cardiovasc Ultrasound       Date:  2012-03-27

8.  Three dimensional echocardiography in congenital heart defects.

Authors:  Girish S Shirali
Journal:  Ann Pediatr Cardiol       Date:  2008-01

9.  Quantitative three-dimensional wall motion analysis predicts ischemic region size and location.

Authors:  Susan L Herz; Takuya Hasegawa; Amgad N Makaryus; Katherine M Parker; Shunichi Homma; Jie Wang; Jeffrey W Holmes
Journal:  Ann Biomed Eng       Date:  2010-01-13       Impact factor: 3.934

10.  Comparison of contrast enhanced three dimensional echocardiography with MIBI gated SPECT for the evaluation of left ventricular function.

Authors:  Bernard Cosyns; David Haberman; Steven Droogmans; Sandrine Warzée; Philippe Mahieu; Eric Laurent; Marie Moonen; Sophie Hernot; Patrizio Lancellotti
Journal:  Cardiovasc Ultrasound       Date:  2009-06-16       Impact factor: 2.062

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.