Effect of surface reaction layer on grindability of cast titanium alloys.

Chikahiro Ohkubo1, Toshio Hosoi, J Phillip Ford, Ikuya Watanabe.   

Abstract

OBJECTIVE: The purpose of this study was to investigate the effect of the cast surface reaction layer on the grindability of titanium alloys, including free-machining titanium alloy (DT2F), and to compare the results with the grindability of two dental casting alloys (gold and Co-Cr).
METHODS: All titanium specimens (pure Ti, Ti-6Al-4V and DT2F) were cast using a centrifugal casting machine in magnesia-based investment molds. Two specimen sizes were used to cast the titanium metals so that the larger castings would be the same size as the smaller gold and Co-Cr alloy specimens after removal of the surface reaction layer (alpha-case). Grindability was measured as volume loss ground from a specimen for 1 min using a handpiece engine with a SiC abrasive wheel at 0.1 kgf and four circumferential wheel speeds.
RESULTS: For the titanium and gold alloys, grindability increased as the rotational speed increased. There was no statistical difference (p>0.05) in grindability for all titanium specimens either with or without the alpha-case. Of the titanium metals tested, Ti-6 Al-4V had the greatest grindability at higher speeds, followed by DT2F and CP Ti. The grindability of the gold alloy was similar to that of Ti-6 Al-4V, whereas the Co-Cr alloy had the lowest grindability. SIGNIFICANCE: The results of this study indicated that the alpha-case did not significantly affect the grindability of the titanium alloys. The free-machining titanium alloy had improved grindability compared to CP Ti.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16083955     DOI: 10.1016/j.dental.2005.04.020

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  2 in total

1.  The effect of abrading and cutting instruments on machinability of dental ceramics.

Authors:  Satoshi Sakoda; Noriko Nakao; Ikuya Watanabe
Journal:  J Mater Sci Mater Med       Date:  2018-03-16       Impact factor: 3.896

2.  In vitro evaluation of a removable partial denture framework using multi-directionally forged titanium.

Authors:  Ginga Suzuki; Satoshi Shimizu; Mana Torii; Ai Tokue; Guo Ying; Masao Yoshinari; Noriyuki Hoshi; Katsuhiko Kimoto; Hiromi Miura; Tohru Hayakawa; Chikahiro Ohkubo
Journal:  J Adv Prosthodont       Date:  2020-12-28       Impact factor: 1.904

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.