Literature DB >> 1608278

[Implantable devices for central venous access in cancer patients. Our experience in 217 cases].

J Torramadé1, J L Hernández, J A Cienfuegos, M Albiach, F Pardo, C Benito, J González, J Voltas.   

Abstract

BACKGROUND: The need of having a venous via available for infusion of chemotherapy treatment along with the difficulty of repeated venous access in oncological patients has lead to the ever more frequent placement of central venous access systems (CVAS) implanted into subcutaneous tissue.
METHODS: From February 1985 to December 1990 217 CVAS were implanted in 205 oncological patients. Twenty-six were Port-a-Cath and 191 were Implantofix.
RESULTS: The average of complications was 0.08/100 days of implantation with an incidence of catheter thrombosis obstruction of 0.03/100 days and system infection of 0.02/100 days. Currently 81 devices continue functioning with 23 having been withdrawn due to complications and 17 for completion of the treatment to which they had been submitted. Ninety-one patients died during this follow up.
CONCLUSIONS: The CVAS are devices which are of easy placement, simple handling, requiring minimum care and few complications. Their efficacy is confirmed by the analysis of the data presented in the present study.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1608278

Source DB:  PubMed          Journal:  Med Clin (Barc)        ISSN: 0025-7753            Impact factor:   1.725


  1 in total

Review 1.  Totally implantable catheter migration and its percutaneous retrieval: case report and review of the literature.

Authors:  E Intagliata; F Basile; R Vecchio
Journal:  G Chir       Date:  2017 Sep-Oct
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.