Literature DB >> 16082724

Fetal trunk and head volume measured by three-dimensional ultrasound at 11 + 0 to 13 + 6 weeks of gestation in chromosomally normal pregnancies.

O Falcon1, C F A Peralta, P Cavoretto, S Faiola, K H Nicolaides.   

Abstract

OBJECTIVE: To establish the relationship between fetal trunk and head volume measured by three-dimensional (3D) ultrasound and gestational age at 11 + 0 to 13 + 6 weeks of gestation.
METHODS: The fetal trunk and head volume were measured using 3D ultrasound in 417 chromosomally normal fetuses from singleton pregnancies at 11 + 0 to 13 + 6 (median, 12 + 0) weeks of gestation. Regression analysis was used to determine the significance of the association between fetal volume and gestational age. The Bland-Altman analysis was used to compare the measurement agreement and bias for a single examiner and between different examiners.
RESULTS: The fetal trunk and head volume increased linearly with gestation from a mean of 5.8 mL at 11 + 0 weeks to 33.3 mL at 13 + 6 weeks and 1 SD was 4.4 mL. There was also a significant linear association between fetal volume and crown-rump length (CRL), from a mean of 5.1 mL at a CRL of 45 mm to 37.5 mL at a CRL of 84 mm and 1 SD was 2.7 mL. However, within this gestational range, a doubling in CRL, from a mean of 48 mm at 11 + 0 weeks to 79 mm at 13 + 6 weeks, was associated with a 5-6-fold increase in fetal volume. The mean difference in fetal volume between paired measurements by the same sonographer was -0.87 mL (95% limits of agreement, -2.31 to 4.05 mL) and the mean difference between paired measurements by two sonographers was -1.09 mL (-5.49 to 3.32 mL).
CONCLUSIONS: 3D ultrasound can provide a reproducible measurement of the fetal trunk and head volume in early pregnancy. At between 11 + 0 and 13 + 6 weeks there is a 5-6-fold increase in fetal volume but only a doubling in CRL.

Mesh:

Year:  2005        PMID: 16082724     DOI: 10.1002/uog.1975

Source DB:  PubMed          Journal:  Ultrasound Obstet Gynecol        ISSN: 0960-7692            Impact factor:   7.299


  3 in total

Review 1.  Three- and 4-dimensional ultrasound in obstetric practice: does it help?

Authors:  Luís F Gonçalves; Wesley Lee; Jimmy Espinoza; Roberto Romero
Journal:  J Ultrasound Med       Date:  2005-12       Impact factor: 2.153

2.  Fetal volume measurements with three dimensional ultrasound in the first trimester of pregnancy, related to pregnancy outcome, a prospective cohort study.

Authors:  Nicol A C Smeets; Marc Prudon; Bjorn Winkens; S Guid Oei
Journal:  BMC Pregnancy Childbirth       Date:  2012-05-28       Impact factor: 3.007

Review 3.  Automated Techniques for the Interpretation of Fetal Abnormalities: A Review.

Authors:  Vidhi Rawat; Alok Jain; Vibhakar Shrimali
Journal:  Appl Bionics Biomech       Date:  2018-06-10       Impact factor: 1.781

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.