Fully 3D Monte Carlo reconstruction in SPECT: a feasibility study.

D Lazaro1, Z El Bitar, V Breton, D Hill, I Buvat.   

Abstract

In single photon emission computed tomography (SPECT) with parallel hole collimation, image reconstruction is usually performed as a set of bidimensional (2D) analytical or iterative reconstructions. This approach ignores the tridimensional (3D) nature of scatter and detector response function that affects the detected signal. To deal with the 3D nature of the image formation process, iterative reconstruction can be used by considering a 3D projector modelling the 3D spread of photons. In this paper, we investigate the value of using accurate Monte Carlo simulations to determine the 3D projector used in a fully 3D Monte Carlo (F3DMC) reconstruction approach. Given the 3D projector modelling all physical effects affecting the imaging process, the reconstruction problem is solved using the maximum likelihood expectation maximization (MLEM) algorithm. To validate the concept, three data sets were simulated and F3DMC was compared with two other 3D reconstruction strategies using analytical corrections for attenuation, scatter and camera point spread function. Results suggest that F3DMC improves spatial resolution, relative and absolute quantitation and signal-to-noise ratio. The practical feasibility of the approach on real data sets is discussed.

Mesh:

Year:  2005        PMID: 16077224     DOI: 10.1088/0031-9155/50/16/006

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  8 in total

1.  A residual correction method for high-resolution PET reconstruction with application to on-the-fly Monte Carlo based model of positron range.

Authors:  Lin Fu; Jinyi Qi
Journal:  Med Phys       Date:  2010-02       Impact factor: 4.071

2.  A detector response function design in pinhole SPECT including geometrical calibration.

Authors:  Z El Bitar; R H Huesman; R Boutchko; Virgile Bekaert; David Brasse; G T Gullberg
Journal:  Phys Med Biol       Date:  2013-03-15       Impact factor: 3.609

3.  Quantitative simultaneous 111In∕99mTc SPECT-CT of osteomyelitis.

Authors:  Morgan Cervo; Victor H Gerbaudo; Mi-Ae Park; Stephen C Moore
Journal:  Med Phys       Date:  2013-08       Impact factor: 4.071

4.  Joint Optimization of Collimator and Reconstruction Parameters in X-Ray Fluorescence Computed Tomography Using Analytical Point Spread Function and Model Observer.

Authors:  Hsin Wu Tseng; Srinivasan Vedantham; Sang Hyun Cho; Andrew Karellas
Journal:  IEEE Trans Biomed Eng       Date:  2019-12-30       Impact factor: 4.538

Review 5.  Monte Carlo methods for device simulations in radiation therapy.

Authors:  Hyojun Park; Harald Paganetti; Jan Schuemann; Xun Jia; Chul Hee Min
Journal:  Phys Med Biol       Date:  2021-09-14       Impact factor: 4.174

6.  A New Approach for Scatter Removal and Attenuation Compensation from SPECT/CT Images.

Authors:  Shabnam Oloomi; Hadi Noori Eskandari; Seyed Rasoul Zakavi; Peter Knoll; Faraz Kalantari; Mohsen Hajizadeh Saffar
Journal:  Iran J Basic Med Sci       Date:  2013-11       Impact factor: 2.699

7.  Monte Carlo-based quantitative pinhole SPECT reconstruction using a ray-tracing back-projector.

Authors:  Mikael Peterson; Johan Gustafsson; Michael Ljungberg
Journal:  EJNMMI Phys       Date:  2017-12-15

8.  Development and validation of a full model of a four-headed neuroimaging single-photon emission computed tomography scanner.

Authors:  Blair A Johnston; Alice Nicol; Alison Bolster; Jamie Wright
Journal:  Nucl Med Commun       Date:  2019-01       Impact factor: 1.690

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.