Literature DB >> 16061568

Comparing the utility of a standard pediatric resuscitation cart with a pediatric resuscitation cart based on the Broselow tape: a randomized, controlled, crossover trial involving simulated resuscitation scenarios.

Swati Agarwal1, Suzanne Swanson, Allison Murphy, Kim Yaeger, Paul Sharek, Louis P Halamek.   

Abstract

BACKGROUND: Access to resuscitation equipment is a critical component in delivering optimal care in pediatric arrest situations. Historically, children's hospitals and clinics have used a standard pediatric resuscitation cart ("standard cart") in which drawers are organized by intervention (eg, intubation module, intravenous module), requiring multiple drawers to be opened during a code. Many emergency departments, however, use a pediatric resuscitation cart based on the Broselow tape ("Broselow cart") in which each drawer is color coded and organized by patient length and weight ranges; each drawer contains all necessary equipment for resuscitation of a patient in that specific length/weight range. A literature review has revealed no studies examining the utility of either cart.
OBJECTIVES: To compare which resuscitation cart organization (standard versus Broselow) allows for faster access to equipment, more accurate selection of appropriately sized equipment, and better user satisfaction. Methodology. We performed a prospective, randomized, controlled, crossover trial in which 21 pediatric health care providers were assigned the role of obtaining the appropriate equipment during 2 standardized, simulated codes alternately using either a standard or Broselow cart. Time to and accuracy of the selection of appropriate medical equipment along with posttesting satisfaction were measured. All simulations were performed in the Center for Advanced Pediatric Education at Stanford University Medical Center (Stanford, CA), a training facility designed to replicate the real medical environment with the technology to allow for videotaping of scenarios.
RESULTS: Of the 21 subjects, 62% found the Broselow cart "easy" or "very easy" to use versus 33% for the standard cart. Of the 21 subjects, 67% preferred the Broselow cart, 10% preferred the standard cart, and 23% indicated no preference. Intubation supplies and nasogastric tubes were found significantly faster when using the Broselow cart (mean time: 29.1 and 20 seconds, respectively) versus the standard cart (mean time: 38.7 and 38.2 seconds, respectively). Correct equipment was provided a statistically significant 99% of the time with the Broselow cart versus 83% of the time with the standard cart. Ten percent of the subjects had prior experience with the Broselow cart versus 62% having experience with the standard cart.
CONCLUSIONS: Despite less prior experience with the Broselow cart, subjects in this study found it easier to use and preferred it over the standard cart. In addition, subjects located intubation equipment and nasogastric tubes significantly faster when using the Broselow cart, and correct equipment was provided significantly more often with the Broselow cart. These data suggest that sites caring for pediatric patients should consider modeling their resuscitation carts after the Broselow cart to enhance provider confidence and patient safety.

Entities:  

Mesh:

Year:  2005        PMID: 16061568     DOI: 10.1542/peds.2005-0320

Source DB:  PubMed          Journal:  Pediatrics        ISSN: 0031-4005            Impact factor:   7.124


  14 in total

Review 1.  Tackling Quality Improvement in the Delivery Room.

Authors:  Wannasiri Lapcharoensap; Henry C Lee
Journal:  Clin Perinatol       Date:  2017-07-14       Impact factor: 3.430

2.  The Accuracy of the Broselow™ Pediatric Emergency Tape for Weight Estimation in an Omani Paediatric Population.

Authors:  Azher A Al-Busaidi; Lakshmanan Jeyaseelan; Hilal M Al-Barwani
Journal:  Sultan Qaboos Univ Med J       Date:  2017-06-20

3.  Pediatric Pharmacists' Participation in Cardiopulmonary Resuscitation Events.

Authors:  Peter N Johnson; Amy Mitchell-Van Steele; Amy L Nguyen; Sylvia Stoffella; J Maria Whitmore
Journal:  J Pediatr Pharmacol Ther       Date:  2018 Nov-Dec

Review 4.  [Tools for drug dosing in life-threatening pediatric emergencies].

Authors:  C G Erker; M Santamaria; M Möllmann
Journal:  Anaesthesist       Date:  2012-11       Impact factor: 1.041

5.  Pilot comparison of three cardiopulmonary resuscitation medication dosing strategies in overweight children.

Authors:  Lyndsy E Pinchevsky; Kimberly A Pesaturo; Brian S Smith; Christian A Hartman
Journal:  J Pediatr Pharmacol Ther       Date:  2010-10

6.  Publishing Trends in the Field of Pediatric Emergency Medicine From 2004 to 2013.

Authors:  Nancy S Rixe; Jeffrey Rixe; Joshua Glick; Erik Lehman; Robert P Olympia
Journal:  Pediatr Emerg Care       Date:  2016-12       Impact factor: 1.454

Review 7.  The Emergency Department Crash Cart: A systematic review and suggested contents.

Authors:  Gabrielle A Jacquet; Bachar Hamade; Karim A Diab; Rasha Sawaya; Gilbert Abou Dagher; Eveline Hitti; Jamil D Bayram
Journal:  World J Emerg Med       Date:  2018

8.  Pediatric Polytrauma Management.

Authors:  Heike Jakob; Thomas Lustenberger; Dorien Schneidmüller; Anna L Sander; Felix Walcher; Ingo Marzi
Journal:  Eur J Trauma Emerg Surg       Date:  2010-07-29       Impact factor: 3.693

Review 9.  Advancing emergency airway management practice and research.

Authors:  Tadahiro Goto; Yukari Goto; Yusuke Hagiwara; Hiroshi Okamoto; Hiroko Watase; Kohei Hasegawa
Journal:  Acute Med Surg       Date:  2019-05-21

10.  Predicting endotracheal tube size from length: Evaluation of the Broselow tape in Indian children.

Authors:  Shalini Subramanian; Madhavi Nishtala; Chandrika Yabagodu Ramavakoda; Gaurang Kothari
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2018 Jan-Mar
View more