Literature DB >> 16060320

Light-weight lead aprons--light on weight, protection or labelling accuracy?

S Muir1, R McLeod, R Dove.   

Abstract

X-ray transmission tests were performed on a Green-Lite (Infab Corporation) apron/vest combination, and compared to a number of other apron/vest combinations routinely used at Christchurch Hospital as well as a sheet of 0.5 mm lead. The materials were X-rayed using the primary beam of a Philips Optimus 50 X-ray machine over an energy range of 50-125 kVp. The entrance and exit doses were recorded and percentage transmission calculated for each kVp. The Green-Lite apron/vest (labelled as 0.5 mm lead at 85 kVp) relies on the overlap at the front to provide the nominal 0.5 mm protection for both the vest and the apron. It performed significantly worse than 0.5 mm of lead and other 0.5 mm lead equivalent apron/vest combinations and provided between 0.3 and 0.39 mm lead equivalent protection depending on the energy used. Vests from other manufacturers all achieved 0.5 mm lead equivalence for a single layer of vest material over the range of energies tested and so were comparable to 1.0 mm lead when doubled. Some aprons relied on a double layer of material to achieve the 0.5 mm lead equivalence (which was not always made clear on the label), while others stated their lead equivalence for a single layer. This resulted in some confusion among wearers of the aprons as to which apron was better.

Mesh:

Year:  2005        PMID: 16060320     DOI: 10.1007/bf03178704

Source DB:  PubMed          Journal:  Australas Phys Eng Sci Med        ISSN: 0158-9938            Impact factor:   1.430


  4 in total

1.  Endovascular Treatment of a Ruptured Posterior Inferior Cerebellar Artery Aneurysm during Pregnancy.

Authors:  Ki Dae Kim; Chul Hoon Chang; Byung Yon Choi; Young Jin Jung
Journal:  J Korean Neurosurg Soc       Date:  2014-05-31

Review 2.  Neuroanesthesia and pregnancy: Uncharted waters.

Authors:  Shalendra Singh; Navdeep Sethi
Journal:  Med J Armed Forces India       Date:  2018-12-20

3.  Efficiency of lead aprons in blocking radiation - how protective are they?

Authors:  Seung-Jae Hyun; Ki-Jeong Kim; Tae-Ahn Jahng; Hyun-Jib Kim
Journal:  Heliyon       Date:  2016-05-27

4.  The hidden risk of ionizing radiation in the operating room: a survey among 258 orthopaedic surgeons in Brazil.

Authors:  Robinson Esteves Pires; Igor Guedes Nogueira Reis; Ângelo Ribeiro Vaz de Faria; Vincenzo Giordano; Pedro José Labronici; William Dias Belangero
Journal:  Patient Saf Surg       Date:  2020-04-22
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.