Literature DB >> 16053563

Calibration models for the vinyl acetate concentration in ethylene-vinyl acetate copolymers and its on-line monitoring by near-infrared spectroscopy and chemometrics: use of band shifts associated with variations in the vinyl acetate concentration to improve the models.

Masahiro Watari1, Yukihiro Ozaki.   

Abstract

The present study investigates calibration models for the vinyl acetate (VA) concentration in ethylene-vinyl acetate (EVA) copolymers and its on-line monitoring by near-infrared (NIR) spectroscopy and chemometrics. The key point in the present study is to make use of band shifts associated with concentration changes in the vinyl acetate (VA) for the improvement of the models. NIR spectra of EVA in melt and solid states were measured by a Fourier transform near-infrared (FT-NIR) on-line monitoring system and a FT-NIR laboratory system. Some of the bands in the NIR spectra for both states show significant shifts with the variations in the VA concentration. The peak shifts induced by the VA concentration changes are larger in the solid-state EVA than those in the melt-state EVA. We have developed calibration models for the VA concentration in the solid-state EVA and investigated how to improve the calibration models. The factor analysis of partial least squares (PLS) regression has suggested that the wavenumber shifts caused by the VA concentration changes affect the calibration models for the VA concentration in EVA. From the analysis, it has been proposed that the wavenumbers in the spectrum of one sample in nine EVA samples (VA concentration range: 0-41.1%) are shifted for the improvement of the calibration models, and the effects of the proposed method have been confirmed by using the PLS calibration models for the VA concentration in the solid EVA samples. As the next step, the effects of the wavenumber shift method have been explored for the calibration models for the VA concentration in the melt-state EVA. After that, the discrimination method using the score plots of PLS and the application sequence for the on-line monitoring to use the proposed wavenumber shift method were studied. The simulation results using the discrimination and wavenumber shift methods have shown that those methods are very effective to improve the predicted values of the calibration models for the on-line monitoring of the VA concentration in the melt-state EVA.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16053563     DOI: 10.1366/0003702054411571

Source DB:  PubMed          Journal:  Appl Spectrosc        ISSN: 0003-7028            Impact factor:   2.388


  2 in total

1.  Plant roots and spectroscopic methods - analyzing species, biomass and vitality.

Authors:  Boris Rewald; Catharina Meinen
Journal:  Front Plant Sci       Date:  2013-10-09       Impact factor: 5.753

2.  SiO2-Ag Composite as a Highly Virucidal Material: A Roadmap that Rapidly Eliminates SARS-CoV-2.

Authors:  Marcelo Assis; Luiz Gustavo P Simoes; Guilherme C Tremiliosi; Dyovani Coelho; Daniel T Minozzi; Renato I Santos; Daiane C B Vilela; Jeziel Rodrigues do Santos; Lara Kelly Ribeiro; Ieda Lucia Viana Rosa; Lucia Helena Mascaro; Juan Andrés; Elson Longo
Journal:  Nanomaterials (Basel)       Date:  2021-03-04       Impact factor: 5.076

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.