Literature DB >> 16053558

Middle infrared, quantum cascade laser optoelectronic absorption system for monitoring glucose in serum.

W Blake Martin1, Sergey Mirov, Ramakrishna Venugopalan.   

Abstract

Advances in middle infrared technology are leading researchers beyond the Fourier transform infrared spectrometer and to the quantum cascade laser. While most research focuses on gas-phase detection, recent research explores its use for condensed-phase matter studies. This work investigates its use for monitoring biologically relevant samples of glucose in serum. Samples with physiological glucose concentrations were monitored with a laser at 1036 cm-1. A 0.992 R2 linearity value was observed. In addition, using another laser at 1194 cm-1 as a measure of the background spectroscopic characteristics, a linearity of 0.998 R2 was observed. The average predictive standard errors of the mean (SEM) were 32.5 and 24.7 mg/dL, respectively, for each method. Quantum cascade lasers could be used to develop middle infrared devices for uses beyond the confines of the laboratory.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16053558     DOI: 10.1366/0003702054411580

Source DB:  PubMed          Journal:  Appl Spectrosc        ISSN: 0003-7028            Impact factor:   2.388


  6 in total

1.  Automated blood sampling and glucose sensing in critical care settings.

Authors:  Kislaya Kunjan; Frank P Lloyd
Journal:  J Diabetes Sci Technol       Date:  2008-03

2.  In vitro glucose measurement using tunable mid-infrared laser spectroscopy combined with fiber-optic sensor.

Authors:  Songlin Yu; Dachao Li; Hao Chong; Changyue Sun; Haixia Yu; Kexin Xu
Journal:  Biomed Opt Express       Date:  2013-12-17       Impact factor: 3.732

3.  Noninvasive glucose detection in human skin using wavelength modulated differential laser photothermal radiometry.

Authors:  Xinxin Guo; Andreas Mandelis; Bernard Zinman
Journal:  Biomed Opt Express       Date:  2012-10-29       Impact factor: 3.732

4.  Infrared Spectroscopy with a Fiber-Coupled Quantum Cascade Laser for Attenuated Total Reflection Measurements Towards Biomedical Applications.

Authors:  Ine L Jernelv; Karina Strøm; Dag Roar Hjelme; Astrid Aksnes
Journal:  Sensors (Basel)       Date:  2019-11-23       Impact factor: 3.576

5.  In vitro measurements of physiological glucose concentrations in biological fluids using mid-infrared light.

Authors:  Sabbir Liakat; Kevin A Bors; Tzu-Yung Huang; Anna P M Michel; Eric Zanghi; Claire F Gmachl
Journal:  Biomed Opt Express       Date:  2013-06-11       Impact factor: 3.732

Review 6.  Recent advances in application of biosensors in tissue engineering.

Authors:  Anwarul Hasan; Md Nurunnabi; Mahboob Morshed; Arghya Paul; Alessandro Polini; Tapas Kuila; Moustafa Al Hariri; Yong-kyu Lee; Ayad A Jaffa
Journal:  Biomed Res Int       Date:  2014-08-06       Impact factor: 3.411

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.