Abstract
In order to rapidly detect and differentiate Newcastle disease virus (NDV) isolates, a method based on real-time PCR SYBR Green I melting-curve analysis of the fusion (F) protein gene was developed. The detection limit of real-time PCR was 9 x 10(2) plasmid copies and was 100 times more sensitive than conventional PCR. Thirty eight reference NDV strains were rapidly identified by their distinctive melting temperatures (T(m)s): 89.23 +/- 0.27 degrees C for velogenic strains, 90.17 +/- 0.35 degrees C for pigeon mesogenic strains, 91.25 +/- 0.14 degrees C for two lentogenic strains (B1 and Ishii). No amplification was detected from unrelated RNA samples by this method. This real-time PCR directly detected NDV from infected tissues and eliminated the gel electrophoretic step for analyzing PCR product using ethidium bromide. The total time for a PCR run was less than 1 hour. The results obtained in this study showed that the real-time PCR presented here is a good screening test for the identification of NDV.Entities:
Mesh:
Substances:
Year: 2005 PMID: 16052279 DOI: 10.1007/s00705-005-0603-0