Literature DB >> 16051709

Mean aortic pressure is the geometric mean of systolic and diastolic aortic pressure in resting humans.

Denis Chemla1, Isabelle Antony, Karen Zamani, Alain Nitenberg.   

Abstract

The aim of our study was twofold: 1) to establish a mathematical link between mean aortic pressure (MAP) and systolic (SAP) and diastolic aortic pressures (DAP) by testing the hypothesis that either the geometric mean or the harmonic mean of SAP and DAP were reliable MAP estimates; and 2) to critically evaluate three empirical formulas recently proposed to estimate MAP. High-fidelity pressures were recorded at rest at the aortic root level in controls (n = 31) and in subjects with various forms of cardiovascular diseases (n = 108). The time-averaged MAP and the pulse pressure (PP = SAP - DAP) were calculated. The MAP ranged from 66 to 160 mmHg [mean = 107.9 mmHg (SD 18.2)]. The geometric mean, i.e., the square root of the product of SAP and DAP, furnished a reliable estimate of MAP [mean bias = 0.3 mmHg (SD 2.7)]. The harmonic mean was inaccurate. The following MAP formulas were also tested: DAP + 0.412 PP (Meaney E, Alva F, Meaney A, Alva J, and Webel R. Heart 84: 64, 2000), DAP + 0.33 PP + 5 mmHg [Chemla D, Hébert JL, Aptecar E, Mazoit JX, Zamani K, Frank R, Fontaine G, Nitenberg A, and Lecarpentier Y. Clin Sci (Lond) 103: 7-13, 2002], and DAP + [0.33 + (heart rate x 0.0012)] PP (Razminia M, Trivedi A, Molnar J, Elbzour M, Guerrero M, Salem Y, Ahmed A, Khosla S, Lubell DL. Catheter Cardiovasc Interv 63: 419-425, 2004). They all provided accurate and precise estimates of MAP [mean bias = -0.2 (SD 2.9), -0.3 (SD 2.7), and 0.1 mmHg (SD 2.9), respectively]. The implications of the geometric mean pressure strictly pertained to the central (not peripheral) level. It was demonstrated that the fractional systolic (SAP/MAP) and diastolic (DAP/MAP) pressures were reciprocal estimates of aortic pulsatility and that the SAP times DAP product matched the total peripheral resistance times cardiac power product. In conclusion, although the previously described thumb-rules applied, the "geometric MAP" appears more valuable as it established a simple mathematical link between the steady and pulsatile component of aortic pressure.

Entities:  

Mesh:

Year:  2005        PMID: 16051709     DOI: 10.1152/japplphysiol.00713.2005

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  6 in total

1.  Pharmacological inhibition of S-nitrosoglutathione reductase improves endothelial vasodilatory function in rats in vivo.

Authors:  Qiumei Chen; Richard E Sievers; Monika Varga; Sourabh Kharait; Daniel J Haddad; Aaron K Patton; Christopher S Delany; Sarah C Mutka; Joan P Blonder; Gregory P Dubé; Gary J Rosenthal; Matthew L Springer
Journal:  J Appl Physiol (1985)       Date:  2013-01-24

2.  Mean pulmonary artery pressure estimated from systolic and diastolic pulmonary artery pressure in children with congenital heart disease: an invasive study.

Authors:  Denis Chemla; Viginie Lambert; Jean Losay
Journal:  Pediatr Cardiol       Date:  2009-11       Impact factor: 1.655

3.  New Method to Estimate Central Systolic Blood Pressure From Peripheral Pressure: A Proof of Concept and Validation Study.

Authors:  Denis Chemla; Sandrine Millasseau; Olfa Hamzaoui; Jean-Louis Teboul; Xavier Monnet; Frédéric Michard; Mathieu Jozwiak
Journal:  Front Cardiovasc Med       Date:  2021-12-15

4.  Pulsatile pulmonary artery pressure in a large animal model of chronic thromboembolic pulmonary hypertension: Similarities and differences with human data.

Authors:  David Boulate; Fanny Loisel; Mathieu Coblence; Bastien Provost; Alban Todesco; Benoit Decante; Antoine Beurnier; Philippe Herve; Frédéric Perros; Marc Humbert; Elie Fadel; Olaf Mercier; Denis Chemla
Journal:  Pulm Circ       Date:  2022-01-12       Impact factor: 2.886

5.  Effects of squatting with elastic bands or conventional resistance-training equipment at different effort levels in post-exercise intraocular pressure of healthy men.

Authors:  Javier Gene-Morales; Andrés Gené-Sampedro; Rosario Salvador-Palmer; Juan C Colado
Journal:  Biol Sport       Date:  2021-11-10       Impact factor: 4.606

6.  Integration of inspiratory and expiratory intra-abdominal pressure: a novel concept looking at mean intra-abdominal pressure.

Authors:  Siavash Ahmadi-Noorbakhsh; Manu Lng Malbrain
Journal:  Ann Intensive Care       Date:  2012-12-20       Impact factor: 6.925

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.