Literature DB >> 16051343

The impact of size of the adnexal mass on the accuracy of frozen section diagnosis.

Peggy M A J Geomini1, Laura D Zuurendonk, Gérard L Bremer, Jan de Graaff, Roy F P M Kruitwagen, Ben W J Mol.   

Abstract

OBJECTIVE: We recently showed that frozen section diagnosis has an almost perfect specificity for the diagnosis of malignancy in an adnexal mass, whereas the sensitivity was, though good, not perfect. The aim of the present study was to examine whether the accuracy of frozen section diagnosis is affected by the size of the adnexal masses.
METHODS: We included women that underwent frozen section diagnosis for adnexal mass surgery. For each patient we recorded serum CA125 level, menopausal status, tumour size, and histologic classification both at frozen section diagnosis and at definite histological examination. We calculated sensitivity and specificity of frozen section diagnoses, both in tumours below and above 10 cm diameter.
RESULTS: We included 257 patients, of whom 142 had a benign tumour, 28 had a borderline tumour and 87 had a malignant tumour at definitive histological assessment. In case frozen section diagnosis showed malignancy, this was always confirmed at final histological assessment. In women with a tumour <10 cm, there was only 1 false negative diagnosis in 50 women with a benign frozen section diagnosis, whereas there were 11 false negative diagnoses in 97 women in women with a tumour > or = 10 cm. The corresponding likelihood ratios of a benign diagnosis for presence of malignancy were .15 for tumours > or = 10 cm and 0.03 for tumours <10 cm, respectively.
CONCLUSION: The accuracy of frozen section diagnosis is dependent on tumour size. In adnexal masses > or = 10 cm, a benign result of the frozen section diagnosis is less reliable than in women with a tumour <10 in cm.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16051343     DOI: 10.1016/j.ygyno.2005.06.027

Source DB:  PubMed          Journal:  Gynecol Oncol        ISSN: 0090-8258            Impact factor:   5.482


  4 in total

1.  Accuracy of intraoperative frozen section in the evaluation of patients with adnexal mass: retrospective analysis of 748 cases with multivariate regression analysis.

Authors:  Derman Basaran; M Coskun Salman; Gokhan Boyraz; Ilker Selcuk; Alp Usubutun; Nejat Ozgul; Kunter Yuce
Journal:  Pathol Oncol Res       Date:  2014-05-22       Impact factor: 3.201

2.  Management of a suspicious adnexal mass: a clinical practice guideline.

Authors:  J E Dodge; A L Covens; C Lacchetti; L M Elit; T Le; M Devries-Aboud; M Fung-Kee-Fung
Journal:  Curr Oncol       Date:  2012-08       Impact factor: 3.677

3.  Diagnostic accuracy of frozen section analysis of borderline ovarian tumors: a meta-analysis with emphasis on misdiagnosis factors.

Authors:  Zhen Huang; Li Li; ChengCheng Li; Samuel Ngaujah; Shu Yao; Ran Chu; Lin Xie; XingSheng Yang; Xiangning Zhang; Peishu Liu; Jie Jiang; Youzhong Zhang; Baoxia Cui; Kun Song; Beihua Kong
Journal:  J Cancer       Date:  2018-07-16       Impact factor: 4.207

4.  SERS-based detection of haptoglobin in ovarian cyst fluid as a point-of-care diagnostic assay for epithelial ovarian cancer.

Authors:  Jayakumar Perumal; Aniza Puteri Mahyuddin; Ghayathri Balasundaram; Douglas Goh; Chit Yaw Fu; Agne Kazakeviciute; U S Dinish; Mahesh Choolani; Malini Olivo
Journal:  Cancer Manag Res       Date:  2019-01-31       Impact factor: 3.989

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.