Ultrasound research scanner for real-time synthetic aperture data acquisition.

Jørgen Arendt Jensen1, Ole Holm, Lars Joost Jensen, Henrik Bendsen, Svetoslav Ivanov Nikolov, Borislav Gueorguiev Tomov, Peter Munk, Martin Hansen, Kent Salomonsen, Johnny Hansen, Kim Gormsen, Henrik Møller Pedersen, Kim L Gammelmark.   

Abstract

Conventional ultrasound systems acquire ultrasound data sequentially one image line at a time. The architecture of these systems is therefore also sequential in nature and processes most of the data in a sequential pipeline. This often makes it difficult to implement radically different imaging strategies on the platforms and makes the scanners less accessible for research purposes. A system designed for imaging research flexibility is the prime concern. The possibility of sending out arbitrary signals and the storage of data from all transducer elements for 5 to 10 seconds allows clinical evaluation of synthetic aperture and 3D imaging. This paper describes a real-time system specifically designed for research purposes. The system can acquire multichannel data in real-time from multi-element ultrasound transducers, and can perform some real-time processing on the acquired data. The system is capable of performing real-time beamforming for conventional imaging methods using linear, phased, and convex arrays. Image acquisition modes can be intermixed, and this makes it possible to perform initial trials in a clinical environment with new imaging modalities for synthetic aperture imaging, 2D and 3D B-mode, and velocity imaging using advanced coded emissions. The system can be used with 128-element transducers and can excite 128 transducer elements and receive and sample data from 64 channels simultaneously at 40 MHz with 12-bit precision. Two-to-one multiplexing in receive can be used to cover 128 receive channels. Data can be beamformed in real time using the system's 80 signal processing units, or it can be stored directly in RAM. The system has 16 Gbytes RAM and can, thus, store more than 3.4 seconds of multichannel data. It is fully software programmable and its signal processing units can also be reconfigured under software control. The control of the system is done over a 100-Mbits/s Ethernet using C and Matlab. Programs for doing, e.g., B-mode imaging can be written directly in Matlab and executed on the system over the net from any workstation running Matlab. The overall system concept is presented along with its implementation and examples of B-mode and in vivo synthetic aperture flow imaging.

Mesh:

Year:  2005        PMID: 16048189     DOI: 10.1109/tuffc.2005.1503974

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  6 in total

1.  Imaging with unfocused regions of focused ultrasound beams.

Authors:  Roger Zemp; Michael F Insana
Journal:  J Acoust Soc Am       Date:  2007-03       Impact factor: 1.840

2.  Medical ultrasound systems.

Authors:  Jeff Powers; Frederick Kremkau
Journal:  Interface Focus       Date:  2011-05-18       Impact factor: 3.906

Review 3.  Targeting of microbubbles: contrast agents for ultrasound molecular imaging.

Authors:  Shiying Wang; John A Hossack; Alexander L Klibanov
Journal:  J Drug Target       Date:  2018-01-09       Impact factor: 5.121

4.  Ultrasound Open Platforms for Next-Generation Imaging Technique Development.

Authors:  Enrico Boni; Alfred C H Yu; Steven Freear; Jorgen Arendt Jensen; Piero Tortoli
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-07       Impact factor: 2.725

5.  A reconfigurable arbitrary waveform generator using PWM modulation for ultrasound research.

Authors:  Amauri A Assef; Joaquim M Maia; Fábio K Schneider; Vera L S N Button; Eduardo T Costa
Journal:  Biomed Eng Online       Date:  2013-03-20       Impact factor: 2.819

Review 6.  Advances in ultrasonography: image formation and quality assessment.

Authors:  Hideyuki Hasegawa
Journal:  J Med Ultrason (2001)       Date:  2021-10-20       Impact factor: 1.314

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.