A computerized wheelchair ergometer. Results of a comparison study.

H E Veeger1, L H van der Woude, R H Rozendal.   

Abstract

To determine the validity of propulsion simulation on a stationary wheelchair ergometer, nine male able-bodied subjects performed submaximal exercise tests on the ergometer and on a motor driven treadmill (MDT). Oxygen uptake, ventilation and stroke parameters were equal for both devices, but heart rate was lower and trunk movement was less for the ergometer test. Analysis of forces and power output on the ergometer indicated that power output was equal for both wheels. The ratio between applied forces and the effectively directed force component was approximately 80%. Also a small torque was applied by the hand onto the handrim surface which contributed to the total propulsion torque around the axle. It is concluded that the ergometer is capable of simulation of wheelchair propulsion, although the different trunk motion may necessitate sufficient wheelchair propulsion experience. Force analysis results are discussed.

Entities:  

Mesh:

Year:  1992        PMID: 1604258

Source DB:  PubMed          Journal:  Scand J Rehabil Med        ISSN: 0036-5505


  6 in total

Review 1.  Wheelchair propulsion biomechanics: implications for wheelchair sports.

Authors:  Y Vanlandewijck; D Theisen; D Daly
Journal:  Sports Med       Date:  2001       Impact factor: 11.136

2.  Differences in performance between trained and untrained subjects during a 30-s sprint test in a wheelchair ergometer.

Authors:  H E Veeger; E M Lute; K Roeleveld; L H van der Woude
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1992

3.  Comparison between overground and dynamometer manual wheelchair propulsion.

Authors:  Alicia M Koontz; Lynn A Worobey; Ian M Rice; Jennifer L Collinger; Michael L Boninger
Journal:  J Appl Biomech       Date:  2011-11-14       Impact factor: 1.833

4.  Design and Fabrication of an Instrumented Handrim to Measure the Kinetic and Kinematic Information by the Hand of User for 3D Analysis of Manual Wheelchair Propulsion Dynamics.

Authors:  Mohammadreza Mallakzadeh; Hossein Akbari
Journal:  J Med Signals Sens       Date:  2014-10

5.  Physiological and biomechanical comparison of overground, treadmill, and ergometer handrim wheelchair propulsion in able-bodied subjects under standardized conditions.

Authors:  Rick de Klerk; Vera Velhorst; Dirkjan H E J Veeger; Lucas H V van der Woude; Riemer J K Vegter
Journal:  J Neuroeng Rehabil       Date:  2020-10-17       Impact factor: 4.262

6.  Variability in bimanual wheelchair propulsion: consistency of two instrumented wheels during handrim wheelchair propulsion on a motor driven treadmill.

Authors:  Riemer J K Vegter; Claudine J Lamoth; Sonja de Groot; Dirkjan H E J Veeger; Lucas H V van der Woude
Journal:  J Neuroeng Rehabil       Date:  2013-01-29       Impact factor: 4.262

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.