Intramyocellular lipid quantification: repeatability with 1H MR spectroscopy.

Martin Torriani1, Bijoy J Thomas, Elkan F Halpern, Megan E Jensen, Daniel I Rosenthal, William E Palmer.   

Abstract

PURPOSE: To prospectively determine the repeatability and variability of tibialis anterior intramyocellular lipid (IMCL) quantifications performed by using 1.5-T hydrogen 1 (1H) magnetic resonance (MR) spectroscopy in healthy subjects.
MATERIALS AND METHODS: Institutional review board approval and written informed consent were obtained for this Health Insurance Portability and Accountability Act-compliant study. The authors examined the anterior tibial muscles of 27 healthy subjects aged 19-48 years (12 men, 15 women; mean age, 25 years) by using single-voxel short-echo-time point-resolved 1H MR spectroscopy. During a first visit, the subjects underwent 1H MR spectroscopy before and after being repositioned in the magnet bore, with voxels carefully placed on the basis of osseous landmarks. Measurements were repeated after a mean interval of 12 days. All spectra were fitted by using Java-based MR user interface (jMRUI) and LCModel software, and lipid peaks were scaled to the unsuppressed water peak (at 4.7 ppm) and the total creatine peak (at approximately 3.0 ppm). A one-way random-effects variance components model was used to determine intraday and intervisit coefficients of variation (CVs). A power analysis was performed to determine the detectable percentage change in lipid measurements for two subject sample sizes.
RESULTS: Measurements of the IMCL methylene protons peak at a resonance of 1.3 ppm scaled to the unsuppressed water peak (IMCL(W)) that were obtained by using jMRUI software yielded the lowest CVs overall (intraday and intervisit CVs, 13.4% and 14.4%, respectively). The random-effects variance components model revealed that nonbiologic factors (equipment and repositioning) accounted for 50% of the total variability in IMCL quantifications. Power analysis for a sample size of 20 subjects revealed that changes in IMCL(W) of greater than 15% could be confidently detected between 1H MR spectroscopic measurements obtained on different days.
CONCLUSION: 1H MR spectroscopy is feasible for repeatable quantification of IMCL concentrations in longitudinal studies of muscle metabolism.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16040916     DOI: 10.1148/radiol.2362041661

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  24 in total

1.  Improved triglycerides and insulin sensitivity with 3 months of acipimox in human immunodeficiency virus-infected patients with hypertriglyceridemia.

Authors:  Colleen Hadigan; James Liebau; Martin Torriani; Rebecca Andersen; Steven Grinspoon
Journal:  J Clin Endocrinol Metab       Date:  2006-08-29       Impact factor: 5.958

2.  Inhibition of acetyl-CoA carboxylase 2 enhances skeletal muscle fatty acid oxidation and improves whole-body glucose homeostasis in db/db mice.

Authors:  S Glund; C Schoelch; L Thomas; H G Niessen; D Stiller; G J Roth; H Neubauer
Journal:  Diabetologia       Date:  2012-04-25       Impact factor: 10.122

3.  Reproducibility of single- and multi-voxel 1H MRS measurements of intramyocellular lipid in overweight and lean subjects under conditions of controlled dietary calorie and fat intake.

Authors:  Wei Shen; Xiangling Mao; Carla Wolper; Stanley Heshka; Stephen Dashnaw; Joy Hirsch; Steven B Heymsfield; Dikoma C Shungu
Journal:  NMR Biomed       Date:  2008-06       Impact factor: 4.044

4.  Intramyocellular lipid quantification: comparison between 3.0- and 1.5-T (1)H-MRS.

Authors:  Martin Torriani; Bijoy J Thomas; Miriam A Bredella; Hugue Ouellette
Journal:  Magn Reson Imaging       Date:  2007-01-18       Impact factor: 2.546

5.  Comparison of 3.0 T proton magnetic resonance spectroscopy short and long echo-time measures of intramyocellular lipids in obese and normal-weight women.

Authors:  Miriam A Bredella; Reza Hosseini Ghomi; Bijoy J Thomas; Karen K Miller; Martin Torriani
Journal:  J Magn Reson Imaging       Date:  2010-08       Impact factor: 4.813

6.  1H MRS of intramyocellular lipids in soleus muscle at 7 T: spectral simplification by using long echo times without water suppression.

Authors:  Jimin Ren; A Dean Sherry; Craig R Malloy
Journal:  Magn Reson Med       Date:  2010-09       Impact factor: 4.668

7.  Effects of lifestyle modification and metformin on atherosclerotic indices among HIV-infected patients with the metabolic syndrome.

Authors:  Kathleen Fitch; Suhny Abbara; Hang Lee; Eleni Stavrou; Rachel Sacks; Theresa Michel; Linda Hemphill; Martin Torriani; Steven Grinspoon
Journal:  AIDS       Date:  2012-03-13       Impact factor: 4.177

8.  Characterization of Intra-myocellular Lipids using 2D Localized Correlated Spectroscopy and Abdominal Fat using MRI in Type 2 Diabetes.

Authors:  Preethi Srikanthan; Aparna Singhal; Cathy C Lee; Rajakumar Nagarajan; Neil Wilson; Christian K Roberts; Theodore J Hahn; M Albert Thomas
Journal:  Magn Reson Insights       Date:  2012-10-15

Review 9.  Metabolism of the right ventricle and the response to hypertrophy and failure.

Authors:  S Elissa Altin; P Christian Schulze
Journal:  Prog Cardiovasc Dis       Date:  2012 Sep-Oct       Impact factor: 8.194

10.  Effect of tesamorelin on visceral fat and liver fat in HIV-infected patients with abdominal fat accumulation: a randomized clinical trial.

Authors:  Takara L Stanley; Meghan N Feldpausch; Jinhee Oh; Karen L Branch; Hang Lee; Martin Torriani; Steven K Grinspoon
Journal:  JAMA       Date:  2014 Jul 23-30       Impact factor: 56.272

View more