Literature DB >> 16040824

Endometrial volume and vascularity measurements by transvaginal 3-dimensional ultrasonography and power Doppler angiography in stimulated and tumoral endometria: an interobserver reproducibility study.

Juan Luis Alcázar1, Luis T Mercé, Manuel García Manero, Santiago Bau, Guillermo López-García.   

Abstract

OBJECTIVE: The purpose of this study was to evaluate interobserver reproducibility of endometrial volume and vascular indices of the endometrium and subendometrial area estimated by 3-dimensional power Doppler angiography (3D-PDA) using the Virtual Organ Computer-Aided Analysis program, determining the influence of the endometrial growth etiology on measurements.
METHODS: Forty women underwent 3D-PDA ultrasonography. Group A comprised 25 women scanned on the day after controlled ovarian stimulation with human chorionic gonadotropin. Group B comprised 15 patients who had uterine bleeding and questionable endometrial thickening. (Histologic evaluation revealed 10 endometrial cancers and 5 endometrial hyperplasias.) A single observer examined all patients and acquired all volume data sets. Forty volume data sets were then analyzed with the Virtual Organ Computer-Aided Analysis program by 2 different observers. Endometrial volume and vascularity indices (vascularization index [VI], flow index [FI], and vascularization flow index [VFI]) of the endometrium and subendometrium were manually calculated in the coronal plane with a 9 degrees rotation step. An intraclass correlation coefficient (ICC) was used to assess interobserver reliability.
RESULTS: Endometrial volume was more reproducible in group A (ICC = 0.98) than in group B (ICC = 0.58) (P < .05). Endometrial and subendometrial VI, FI, and VFI also presented good reproducibility with ICC greater than 0.84. The ICC was not statistically different for endometrial and subendometrial VI, FI, and VFI according to patient group, although subendometrial VFI was less reproducible in group B (ICC = 0.53) than in group A (ICC = 0.88).
CONCLUSIONS: Endometrial volume and endometrial and subendometrial 3D power Doppler indices have acceptable reproducibility. The interobserver reproducibility in tumoral endometrium was more similar than in stimulated endometrium. Our results indicate that 3D-PDA is a reliable method to evaluate physiologic and pathologic endometrial changes.

Entities:  

Mesh:

Year:  2005        PMID: 16040824     DOI: 10.7863/jum.2005.24.8.1091

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  9 in total

Review 1.  Three-dimensional ultrasound as a predictor of pregnancy in patients undergoing ART.

Authors:  Cemil Yaman; Richard Mayer
Journal:  J Turk Ger Gynecol Assoc       Date:  2012-06-01

2.  Value of three dimensional power Doppler ultrasound in prediction of endometrial carcinoma in patients with postmenopausal bleeding.

Authors:  Sherif Hanafi; Ahmed Abou-Gabal; Sherif Akl; Heba Abd El Baset
Journal:  J Turk Ger Gynecol Assoc       Date:  2014-06-01

Review 3.  Three-dimensional ultrasound assessment of endometrial receptivity: a review.

Authors:  Juan Luis Alcázar
Journal:  Reprod Biol Endocrinol       Date:  2006-11-09       Impact factor: 5.211

4.  Endometrial Volume Measured by VOCAL Compared to Office Hysteroscopy for Diagnosis of Endometrial Polyps in Premenopausal Women with Abnormal Uterine Bleeding.

Authors:  Mohamed Laban; Sherif H Hussain; Alaa S Hassanin; Waleed M Khalaf; Mohamed K Etman; Mohammed S E Elsafty; Ahmed M Bahaa Eldin; Ahmad S Hasanien; Noha A Sakna; Mohammed Taema; Mohammed H Mostafa; Marwa M Eisa
Journal:  Obstet Gynecol Int       Date:  2016-11-24

5.  Reliability of Sonographic Estimation of Fetal Weight: A Study of Three Tertiary Hospitals in Nigeria.

Authors:  Cletus Uche Eze; Christopher Chukwuemeka Ohagwu; Livinus Chibuzo Abonyi; Nicholas Kayode Irurhe; Zachaeus Ayo Ibitoye
Journal:  Saudi J Med Med Sci       Date:  2016-11-16

6.  Traditional Chinese herb for low endometrial receptivity and its effect on pregnancy: Protocol for a systematic review and meta-analysis.

Authors:  Mei Jiang; Ling Huang; Xiaohong Gu; Tiegang Liu; Jia Kang; Ting Wang
Journal:  Medicine (Baltimore)       Date:  2019-11       Impact factor: 1.817

7.  Quantitative power Doppler ultrasound measures of peripheral joint synovitis in poor prognosis early rheumatoid arthritis predict radiographic progression.

Authors:  Dee Sreerangaiah; Michael Grayer; Benjamin A Fisher; Meilien Ho; Sonya Abraham; Peter C Taylor
Journal:  Rheumatology (Oxford)       Date:  2015-08-27       Impact factor: 7.580

Review 8.  The current status of three-dimensional ultrasonography in gynaecology.

Authors:  Chiou Li Ong
Journal:  Ultrasonography       Date:  2015-09-25

Review 9.  3D Power Doppler vascular indices as a novel technique in assessing the outcome of minimally invasive techniques in uterine fibroids treatment.

Authors:  Anna Stępniak; Piotr Czuczwar
Journal:  Prz Menopauzalny       Date:  2017-12-30
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.