Literature DB >> 16040117

Qualitative computer aided evaluation of dental impressions in vivo.

Ralph G Luthardt1, Rainer Koch, Heike Rudolph, Michael H Walter.   

Abstract

OBJECTIVES: Clinical investigations dealing with the precision of different impression techniques are rare. Objective of the present study was to develop and evaluate a procedure for the qualitative analysis of the three-dimensional impression precision based on an established in-vitro procedure. The zero hypothesis to be tested was that the precision of impressions does not differ depending on the impression technique used (single-step, monophase and two-step-techniques) and on clinical variables.
METHODS: Digital surface data of patient's teeth prepared for crowns were gathered from standardized manufactured master casts after impressions with three different techniques were taken in a randomized order. Data-sets were analyzed for each patient in comparison with the one-step impression chosen as the reference. The qualitative analysis was limited to data-points within the 99.5%-range. Based on the color-coded representation areas with maximum deviations were determined (preparation margin and the mantle and occlusal surface). To qualitatively analyze the precision of the impression techniques, the hypothesis was tested in linear models for repeated measures factors (p < 0.05).
RESULTS: For the positive 99.5% deviations no variables with significant influence were determined in the statistical analysis. In contrast, the impression technique and the position of the preparation margin significantly influenced the negative 99.5% deviations. SIGNIFICANCE: The influence of clinical parameter on the deviations between impression techniques can be determined reliably using the 99.5 percentile of the deviations. An analysis regarding the areas with maximum deviations showed high clinical relevance. The preparation margin was pointed out as the weak spot of impression taking.

Entities:  

Mesh:

Year:  2005        PMID: 16040117     DOI: 10.1016/j.dental.2005.02.015

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  5 in total

1.  Randomized controlled clinical trial on the three-dimensional accuracy of fast-set impression materials.

Authors:  Heike Rudolph; Sebastian Quaas; Manuela Haim; Jörg Preißler; Michael H Walter; Rainer Koch; Ralph G Luthardt
Journal:  Clin Oral Investig       Date:  2012-08-31       Impact factor: 3.573

2.  Evaluation of fit and efficiency of CAD/CAM fabricated all-ceramic restorations based on direct and indirect digitalization: a double-blinded, randomized clinical trial.

Authors:  Danush Ahrberg; Hans Christoph Lauer; Martin Ahrberg; Paul Weigl
Journal:  Clin Oral Investig       Date:  2015-06-14       Impact factor: 3.573

3.  Accuracy evaluation of a new three-dimensional reproduction method of edentulous dental casts, and wax occlusion rims with jaw relation.

Authors:  Fu-Song Yuan; Yu-Chun Sun; Yong Wang; Pei-Jun Lü
Journal:  Int J Oral Sci       Date:  2013-08-02       Impact factor: 6.344

4.  Comparison of Adaptation between the Major Connectors Fabricated from Intraoral Digital Impressions and Extraoral Digital Impressions.

Authors:  Ning Gan; Yaye Ruan; Jian Sun; Yaoyang Xiong; Ting Jiao
Journal:  Sci Rep       Date:  2018-01-11       Impact factor: 4.379

5.  Accuracy of Gypsum Casts after Different Impression Techniques and Double Pouring.

Authors:  Stephania Caroline Rodolfo Silva; Aion Mangino Messias; Filipe de Oliveira Abi-Rached; Raphael Freitas de Souza; José Maurício Dos Santos Nunes Reis
Journal:  PLoS One       Date:  2016-10-13       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.