Literature DB >> 16039372

Refined myoelectric control in below-elbow amputees using artificial neural networks and a data glove.

Fredrik C P Sebelius1, Birgitta N Rosén, Göran N Lundborg.   

Abstract

PURPOSE: To develop a system for refined motor control of artificial hands based on multiple electromyographic (EMG) recordings, allowing multiple patterns of hand movements.
METHODS: Five subjects with traumatic below-elbow amputations and 1 subject with a congenital below- elbow failure of formation performed 10 imaginary movements with their phantom hand while surface electrodes recorded the EMG data. In a training phase a data glove with 18 degrees of freedom was used for positional recording of movements in the contralateral healthy hand. These movements were performed at the same time as the imaginary movements in the phantom hand. An artificial neural network (ANN) then could be trained to associate the specific EMG patterns recorded from the amputation stump with the analogous specific hand movements synchronously performed in the healthy hand. The ability of the ANN to predict the 10 imaginary movements offline, when they were reflected in a virtual computer hand, was assessed and calculated.
RESULTS: After the ANN was trained the subjects were able to perform and control 10 hand movements in the virtual computer hand. The subjects showed a median performance of 5 types of movement with a high correlation with the movement pattern of the data glove. The subjects seemed to relearn to execute motor commands rapidly that had been learned before the accident, independent of how old the injury was. The subject with congenital below-elbow failure of formation was able to perform and control several hand movements in the computer hand that cannot be performed in a myoelectric prosthesis (eg, opposition of the thumb).
CONCLUSIONS: With the combined use of an ANN and a data glove, acting in concert in a training phase, amputees rapidly can learn to execute several imaginary movements in a virtual computerized hand, this opens promising possibilities for motor control of future hand prostheses.

Entities:  

Mesh:

Year:  2005        PMID: 16039372     DOI: 10.1016/j.jhsa.2005.01.002

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  28 in total

1.  Multigrasp myoelectric control for a transradial prosthesis.

Authors:  Skyler A Dalley; Huseyin Atakan Varol; Michael Goldfarb
Journal:  IEEE Int Conf Rehabil Robot       Date:  2011

2.  Estimation of distal arm joint angles from EMG and shoulder orientation for transhumeral prostheses.

Authors:  Aadeel Akhtar; Navid Aghasadeghi; Levi Hargrove; Timothy Bretl
Journal:  J Electromyogr Kinesiol       Date:  2017-06-11       Impact factor: 2.368

3.  A method for the control of multigrasp myoelectric prosthetic hands.

Authors:  Skyler Ashton Dalley; Huseyin Atakan Varol; Michael Goldfarb
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2011-12-12       Impact factor: 3.802

4.  Pattern recognition control of multifunction myoelectric prostheses by patients with congenital transradial limb defects: a preliminary study.

Authors:  Michael Kryger; Aimee E Schultz; Todd Kuiken
Journal:  Prosthet Orthot Int       Date:  2011-09-29       Impact factor: 1.895

5.  Design and technical construction of a tactile display for sensory feedback in a hand prosthesis system.

Authors:  Christian Antfolk; Christian Balkenius; Göran Lundborg; Birgitta Rosén; Fredrik Sebelius
Journal:  Biomed Eng Online       Date:  2010-09-14       Impact factor: 2.819

6.  Feasibility of EMG-based neural network controller for an upper extremity neuroprosthesis.

Authors:  Juan Gabriel Hincapie; Robert F Kirsch
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2009-02       Impact factor: 3.802

7.  A strategy for identifying locomotion modes using surface electromyography.

Authors:  He Huang; Todd A Kuiken; Robert D Lipschutz
Journal:  IEEE Trans Biomed Eng       Date:  2009-01       Impact factor: 4.538

8.  Quantifying pattern recognition-based myoelectric control of multifunctional transradial prostheses.

Authors:  Guanglin Li; Aimee E Schultz; Todd A Kuiken
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2010-01-12       Impact factor: 3.802

9.  Preliminary functional assessment of a multigrasp myoelectric prosthesis.

Authors:  Skyler A Dalley; Daniel A Bennett; Michael Goldfarb
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2012

10.  Multi-subject/daily-life activity EMG-based control of mechanical hands.

Authors:  Claudio Castellini; Angelo Emanuele Fiorilla; Giulio Sandini
Journal:  J Neuroeng Rehabil       Date:  2009-11-17       Impact factor: 4.262

View more