Literature DB >> 16039211

Prediction of graft flow impairment by intraoperative transit time flow measurement in off-pump coronary artery bypass using arterial grafts.

Ki-Bong Kim1, Chang Hyun Kang, Cheong Lim.   

Abstract

BACKGROUND: We assessed the validity of intraoperative transit time flow measurement (TTFM) in predicting graft flow abnormalities.
METHODS: Intraoperative graft flow measurement using TTFM and early postoperative coronary angiography was performed in 58 patients who underwent total arterial off-pump coronary artery bypass. Five variables (flow pattern, mean flow, pulsatility index, insufficiency ratio, and fast Fourier transformation ratio) were measured and compared between 103 normal and 14 abnormal (occluded or competitive) grafts.
RESULTS: The grafts anastomosed to the right coronary territories showed significantly less diastolic dominant pattern, lower mean flow and fast Fourier transformation ratio, and higher pulsatility index than grafts to the left coronary artery territories (p < 0.05). None of the abnormal grafts showed a diastolic dominant flow pattern. The abnormal grafts demonstrated significantly lower mean flow and fast Fourier transformation ratio and higher pulsatility index and insufficiency ratio than normal grafts (p < 0.05). When our criteria for detection of abnormal graft flow, [(1) systolic dominant or balanced pattern of the flow curve in the left coronary territories, systolic dominant pattern of the flow curve in the right coronary territories; (2) mean flow < 15 mL/min; (3) pulsatility index > 3 in the left coronary territories and > 5 in the right coronary territories; and (4) insufficiency ratio > 2%] were applied, the sensitivity and specificity of TTFM to detect the graft flow abnormality were 96.2% and 76.9%, respectively.
CONCLUSIONS: Our data suggest that TTFM is a reliable intraoperative tool to predict graft flow impairment.

Entities:  

Mesh:

Year:  2005        PMID: 16039211     DOI: 10.1016/j.athoracsur.2005.02.047

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  17 in total

Review 1.  Intraoperative graft assessment during coronary artery bypass surgery.

Authors:  Toshihiro Fukui
Journal:  Gen Thorac Cardiovasc Surg       Date:  2015-01-06

2.  Transit time flow measurement in composite arterial revascularisation.

Authors:  R John L Brereton
Journal:  Ann Cardiothorac Surg       Date:  2018-09

Review 3.  Techniques for intraoperative graft assessment in coronary artery bypass surgery.

Authors:  Lucas B Ohmes; Antonino Di Franco; Gabriele Di Giammarco; Carlo Maria Rosati; Christopher Lau; Leonard N Girardi; Massimo Massetti; Mario Gaudino
Journal:  J Thorac Dis       Date:  2017-04       Impact factor: 2.895

4.  Initial Experience with Epicardial Ultrasound Scanning in Coronary Artery Bypass Grafting.

Authors:  Dae Hyeon Kim; Suk Ho Sohn; Ho Young Hwang
Journal:  Korean J Thorac Cardiovasc Surg       Date:  2020-10-05

5.  Conduits for Coronary Bypass: Arteries Other Than the Internal Thoracic Artery's.

Authors:  Hendrick B Barner
Journal:  Korean J Thorac Cardiovasc Surg       Date:  2013-06-05

6.  Surgical decision making for revascularization of chronically occluded right coronary artery.

Authors:  Andreas Borowski; Erhard Godehardt; Hannan Dalyanoglu
Journal:  Gen Thorac Cardiovasc Surg       Date:  2016-08-08

7.  Maximal blood flow acceleration analysis in the early diastolic phase for aortocoronary artery bypass grafts: a new transit-time flow measurement predictor of graft failure following coronary artery bypass grafting.

Authors:  Takemi Handa; Kazumasa Orihashi; Hideaki Nishimori; Masaki Yamamoto
Journal:  Surg Today       Date:  2016-03-19       Impact factor: 2.549

8.  Predictors of early graft failure after coronary artery bypass grafting for chronic total occlusion.

Authors:  Hideki Oshima; Yoshiyuki Tokuda; Yoshimori Araki; Hideki Ishii; Toyoaki Murohara; Yukio Ozaki; Akihiko Usui
Journal:  Interact Cardiovasc Thorac Surg       Date:  2016-03-30

9.  Comparison of blood flow in single and sequential vein grafts during off-pump coronary artery bypass.

Authors:  Jingxing Li; Chengxiong Gu
Journal:  J Thorac Dis       Date:  2019-08       Impact factor: 2.895

10.  Conduits for coronary bypass: vein grafts.

Authors:  Hendrick B Barner; Emily A Farkas
Journal:  Korean J Thorac Cardiovasc Surg       Date:  2012-10-09
View more