Literature DB >> 16038669

Numerical confusion errors in ishihara testing: findings from a population-based study.

Michael Cosstick1, Dana Robaei, Kathryn Rose, Elena Rochtchina, Paul Mitchell.   

Abstract

PURPOSE: To describe the prevalence of numerical confusion errors in Ishihara testing in a representative sample of Australian children.
DESIGN: Cross-sectional, population-based study.
METHODS: The Sydney Myopia Study examined a representative stratified random cluster sample of 1,741 children (aged 6 years) attending 34 schools in Sydney, Australia (response rate, 78.9%), including color vision tests in 1,735 children. Those with any color vision defects (n = 33; 1.9%; 97% boys) were excluded. Responses for each Ishihara plate were recorded.
RESULTS: Numerical confusion errors were made by 75.8% of children with normal color vision; there was no gender difference. Plates 3 and 7 were particularly prone to numerical confusion errors; 48.4% and 40.8%, respectively, of children misread these plates.
CONCLUSION: Numerical confusion errors in the Ishihara test were relatively common in children with normal color vision. The frequency of such errors could indicate an inherent deficiency in this commonly used test.

Entities:  

Mesh:

Year:  2005        PMID: 16038669     DOI: 10.1016/j.ajo.2005.01.002

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  2 in total

1.  Ishihara test in 3- to 6-year-old children.

Authors:  Sang Yul Choi; Jeong-Min Hwang
Journal:  Jpn J Ophthalmol       Date:  2009-10-22       Impact factor: 2.447

2.  Association Between Color Vision Deficiency and Myopia in Chinese Children Over a Five-Year Period.

Authors:  Jiahe Gan; Shi-Ming Li; David A Atchison; Meng-Tian Kang; Shifei Wei; Xi He; Weiling Bai; He Li; Yuting Kang; Zhining Cai; Lei Li; Zi-Bing Jin; Ningli Wang
Journal:  Invest Ophthalmol Vis Sci       Date:  2022-02-01       Impact factor: 4.799

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.