Literature DB >> 16036757

Performance of a portable whole-body mouse exposure system.

Michael J Oldham1, Robert F Phalen, Risa J Robinson, Michael T Kleinman.   

Abstract

A mobile whole-body exposure system was developed for exposing mice to concentrated ambient particulate matter smaller than 2.5 microm in mass median aerodynamic diameter (MMAD). Each 20-L exposure cage was designed to hold 9 mice within individual compartments. This allowed for transport and subsequent exposure. Airflow mixing and the potential for stagnant areas within the compartments were modeled using computational fluid dynamic modeling (CFD). CFD analysis showed no stagnant areas and good mixing throughout the exposure cage. The actual performance of the exposure system was determined for 0.5 to 2.0 microm diameter aerosols by measuring (1) uniformity of aerosol distribution and (2) particle deposition in the tracheobronchial and pulmonary regions of mice exposed in the system. A 0.6-microm MMAD (GSD=2.0) cigarette smoke aerosol was used to experimentally measure the uniformity of aerosol distribution to the nine individual compartments. The average data from three runs showed no statistically significant difference among individual compartments. Particle deposition efficiency in adult male BALB/c mice was measured after exposure (30 min) in the system using monodisperse fluorescent polystyrene latex particles (0.5, 1, and 2 microm aerodynamic diameter). The measured deposition efficiency in this mobile exposure system for the combined tracheobronchial and pulmonary regions of the adult male BALBc mice was 21% for 0.5 microm, 11% for 1.0 microm, and 6.5% for 2.0 microm particles. These deposition efficiencies are similar to those reported for mice exposed in a nose-only exposure system, which indicates that particle losses to animal fur and exposure system surfaces were acceptable.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 16036757     DOI: 10.1080/08958370490464670

Source DB:  PubMed          Journal:  Inhal Toxicol        ISSN: 0895-8378            Impact factor:   2.724


  5 in total

1.  Ambient particulate pollutants in the ultrafine range promote early atherosclerosis and systemic oxidative stress.

Authors:  Jesus A Araujo; Berenice Barajas; Michael Kleinman; Xuping Wang; Brian J Bennett; Ke Wei Gong; Mohamad Navab; Jack Harkema; Constantinos Sioutas; Aldons J Lusis; Andre E Nel
Journal:  Circ Res       Date:  2008-01-17       Impact factor: 17.367

2.  Inhaled ultrafine particulate matter affects CNS inflammatory processes and may act via MAP kinase signaling pathways.

Authors:  M T Kleinman; J A Araujo; A Nel; C Sioutas; A Campbell; P Q Cong; H Li; S C Bondy
Journal:  Toxicol Lett       Date:  2008-03-18       Impact factor: 4.372

3.  Breath-by-breath measurement of particle deposition in the lung of spontaneously breathing rats.

Authors:  S Karrasch; G Eder; I Bolle; A Tsuda; H Schulz
Journal:  J Appl Physiol (1985)       Date:  2009-07-30

4.  Exposure to environmentally relevant concentrations of ambient fine particulate matter (PM2.5) depletes the ovarian follicle reserve and causes sex-dependent cardiovascular changes in apolipoprotein E null mice.

Authors:  Ulrike Luderer; Jinhwan Lim; Laura Ortiz; Johnny D Nguyen; Joyce H Shin; Barrett D Allen; Lisa S Liao; Kelli Malott; Veronique Perraud; Lisa M Wingen; Rebecca J Arechavala; Bishop Bliss; David A Herman; Michael T Kleinman
Journal:  Part Fibre Toxicol       Date:  2022-01-07       Impact factor: 9.400

5.  Air-pollutant chemicals and oxidized lipids exhibit genome-wide synergistic effects on endothelial cells.

Authors:  Ke Wei Gong; Wei Zhao; Ning Li; Berenice Barajas; Michael Kleinman; Constantinos Sioutas; Steve Horvath; Aldons J Lusis; Andre Nel; Jesus A Araujo
Journal:  Genome Biol       Date:  2007       Impact factor: 13.583

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.