Literature DB >> 16036200

One hundred cases of laparoscopic subtotal hysterectomy using the PK and Lap Loop systems.

John Erian1, Tarek El-Toukhy, Stefanos Chandakas, Theo Theodoridis, Nicholas Hill.   

Abstract

STUDY
OBJECTIVE: To evaluate the safety and short-term outcomes of laparoscopic subtotal hysterectomy using the PK and Lap Loop systems.
DESIGN: Prospective observational study (Canadian Task Force classification II-2).
SETTING: Princess Royal University and Chelsfield Park Hospitals, Kent, UK. PATIENTS: One hundred women who underwent laparoscopic subtotal hysterectomy for menorrhagia from February 2003 through July 2004. INTERVENTION: The procedure was performed using the Plasma Kinetic (PK) system to seal the vascular pedicles and the Lap Loop system to separate the uterus at the level of the internal os. The uterus was removed from the abdominal cavity mainly by morcellation or posterior colpotomy.
MEASUREMENTS AND MAIN RESULTS: Of 100 patients, 59 were operated on as outpatients. Mean patient age was 44.6 years, median parity was 2, mean body mass index was 26.8, and mean duration of symptoms was 4 years. Clinically, the uterus was enlarged in 70 patients, and preoperative ultrasound scanning suggested the presence of uterine myomas in 42 patients. In addition to hysterectomy, 47 patients had concomitant pelvic surgery. The mean total operating time was 45.5 minutes, and mean estimated blood loss was 114 mL. The overall major complication rate was 2%; two patients required blood transfusion after surgery. There were no bowel or urinary tract injuries, unintended laparotomy, return to operating room, or anesthetic complications. At follow-up, all patients were satisfied with surgery.
CONCLUSION: Laparoscopic subtotal hysterectomy using the PK and Lap Loop systems for treatment of therapy-resistant menorrhagia is safe, can be performed as an outpatient procedure, and is associated with reduced operating time and high patient satisfaction.

Entities:  

Mesh:

Year:  2005        PMID: 16036200     DOI: 10.1016/j.jmig.2005.05.007

Source DB:  PubMed          Journal:  J Minim Invasive Gynecol        ISSN: 1553-4650            Impact factor:   4.137


  1 in total

1.  Cervical Detachment Using Monopolar SupraLoop™ Electrode versus Monopolar Needle in Laparoscopic Supracervical Hysterectomy (LSH): An Interventional, Comparative Cohort Study.

Authors:  S Brucker; R Rothmund; B Krämer; F Neis; B Schönfisch; W Zubke; F A Taran; M Wallwiener
Journal:  Geburtshilfe Frauenheilkd       Date:  2013-11       Impact factor: 2.915

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.