Literature DB >> 16036199

Breast ductoscopy with a 0.55-mm mini-endoscope for direct visualization of intraductal lesions.

Volker R Jacobs1, Marion Kiechle, Birgit Plattner, Thorsten Fischer, Stefan Paepke.   

Abstract

Standard radiologic examinations of breast duct lesions can give only indirect information. Mini-endoscopy with a breast ductoscope of only 0.55 mm offers direct visualization of the lesion and helps in the decision to perform or avoid exploratory breast tissue resection. We used a LaDuScope (PolyDiagnost, Pfaffenhofen, Germany) with a 0.55- or 0.95-mm outer diameter and a 75-mm working length from October 2003 through July 2004 on 11 women (average age of 48.3 years [range 36-69 years]) with suspicious nipple discharge. The optics have zero-degree direct view, 70-degree field vision, and 3000 or 6000 pixel resolution. Breast ducts and walls could be easily inspected; and irrigation of breast ducts, aspiration, and use of cytology brush were possible under visual control. We had no intraoperative or postoperative complications. The new procedure of mini-ductoscopy is feasible, safe, and helpful as an additional ambulatory diagnostic method for visual inspection of breast ducts. This instrument demonstrates the latest advances of technology and a trend toward less-invasive diagnostics for breast duct lesions.

Entities:  

Mesh:

Year:  2005        PMID: 16036199     DOI: 10.1016/j.jmig.2005.04.004

Source DB:  PubMed          Journal:  J Minim Invasive Gynecol        ISSN: 1553-4650            Impact factor:   4.137


  9 in total

1.  [Sialendoscopy].

Authors:  U W Geisthoff
Journal:  HNO       Date:  2008-02       Impact factor: 1.284

2.  A novel multipurpose mini-endoscope for frontal sinus endoscopy "sinus view".

Authors:  Basel Al Kadah; Victoria Bozzato; Alessandro Bozzato; George Papaspyrou; Bernhard Schick
Journal:  Eur Arch Otorhinolaryngol       Date:  2014-09-03       Impact factor: 2.503

3.  Miniature grating for spectrally-encoded endoscopy.

Authors:  Dongkyun Kang; Ramses V Martinez; George M Whitesides; Guillermo J Tearney
Journal:  Lab Chip       Date:  2013-05-07       Impact factor: 6.799

4.  Spectrally-encoded color imaging.

Authors:  DongKyun Kang; Dvir Yelin; Brett E Bouma; Guillermo J Tearney
Journal:  Opt Express       Date:  2009-08-17       Impact factor: 3.894

5.  Dual-channel spectrally encoded endoscopic probe.

Authors:  Guy Engel; Hadar Genish; Michael Rosenbluh; Dvir Yelin
Journal:  Biomed Opt Express       Date:  2012-07-16       Impact factor: 3.732

6.  Breast papillomas: current management with a focus on a new diagnostic and therapeutic modality.

Authors:  W Al Sarakbi; D Worku; P F Escobar; K Mokbel
Journal:  Int Semin Surg Oncol       Date:  2006-01-17

7.  Patient-reported outcomes of ductoscopy procedures for pathologic nipple discharge.

Authors:  M D Filipe; J M Simons; L Moeliker; L Waaijer; M R Vriens; P J van Diest; A J Witkamp
Journal:  Breast Cancer       Date:  2020-11-12       Impact factor: 4.239

8.  Detection of breast cancer precursor lesions by autofluorescence ductoscopy.

Authors:  Laurien Waaijer; Mando D Filipe; Janine Simons; Carmen C van der Pol; Tjeerd de Boorder; Paul J van Diest; Arjen Joost Witkamp
Journal:  Breast Cancer       Date:  2020-07-28       Impact factor: 4.239

Review 9.  Meta-analysis and cost-effectiveness of ductoscopy, duct excision surgery and MRI for the diagnosis and treatment of patients with pathological nipple discharge.

Authors:  M D Filipe; S I S Patuleia; M R Vriens; P J van Diest; A J Witkamp
Journal:  Breast Cancer Res Treat       Date:  2021-01-21       Impact factor: 4.872

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.